Basit öğe kaydını göster

dc.contributor.authorÇataltepe, Aziz
dc.contributor.authorİyetin, Yusuf
dc.date.accessioned2023-11-14T07:18:43Z
dc.date.available2023-11-14T07:18:43Z
dc.date.issued2023en_US
dc.identifier.citationÇataltepe, A. ve İyetin, Y. (2023). The press-fit technique without screws and bone graft can be used as an alternative method in Crowe type II and III hip dysplasia. Turkish Journal of Medical Sciences, 53(5), 1448-1457. https://dx.doi.org/10.55730/1300-0144.5712en_US
dc.identifier.issn1300-0144
dc.identifier.urihttps://dx.doi.org/10.55730/1300-0144.5712
dc.identifier.urihttps://hdl.handle.net/20.500.12511/11772
dc.description.abstractBackground/aim: Developmental dysplasia of the hip (DDH) is the most common cause of secondary hip arthrosis. The primary purpose of this study was to assess the results of an oversized hemispherical cup via the press-fit technique used for Crowe type II and III DDH without screws and to determine if adequate medialization and initial stability of the acetabular component would allow us to avoid screw and graft use. Materials and methods: Between February 2012 and May 2020, the current study analyzed 43 hips with Crowe type II and III DDH treated with a porous-coated cup by placing the press-fit technique or screw. The acetabular cup was fixed with the press-fit technique without additional screws in 27 hips and with screws in 16 hips. The inclusion criterion in this study was a minimum 2-year-period after the surgery. Results: The mean duration of follow-up was 6.83 ± 2.67 years in the press-fit group and 6.21 ± 2.01 years in the screw group. The mean age of the patients was 47.96 ± 12.37 years in the press-fit group and 50.5 ± 12.37 years in the screw group. Measurements revealed that the hip center of rotation (HCR) was located more medially and superiorly postoperatively than preoperatively in both groups. The mean cup coverage in the screw group was 85.58% ± 7.51% (75.3%–97.2%), while it was less than 90.41% ± 6.15% (76.3%–98.2%) in the press-fit group (p = 0.038). No component was revised because of loosening, and all of the implants were radiologically stable within the observation period. No statistically significant differences were observed regarding the postoperative limp-length discrepancy between the groups (p = 0.496). Conclusion: Press-fit implantation of a porous-coated acetabular component without screws can also be used as an alternative method for THA in Crowe type II and III DDH. The initial stability was obtained using the press-fit technique with a small cup positioned more medially and superiorly, which may allow the surgeon to avoid screw and graft use.en_US
dc.language.isoengen_US
dc.publisherTurkiye Kliniklerien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution 4.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectDevelopmental Dysplasia of the Hipen_US
dc.subjectMedializationen_US
dc.subjectPress-Fit Techniqueen_US
dc.subjectSmall Cupen_US
dc.subjectTotal Hip Arthroplastyen_US
dc.titleThe press-fit technique without screws and bone graft can be used as an alternative method in Crowe type II and III hip dysplasiaen_US
dc.typearticleen_US
dc.relation.ispartofTurkish Journal of Medical Sciencesen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Ortopedi ve Travmatoloji Ana Bilim Dalıen_US
dc.authorid0000-0001-9785-9062en_US
dc.identifier.volume53en_US
dc.identifier.issue5en_US
dc.identifier.startpage1448en_US
dc.identifier.endpage1457en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.55730/1300-0144.5712en_US
dc.institutionauthorÇataltepe, Aziz
dc.identifier.scopus2-s2.0-85175572715en_US
dc.identifier.scopusqualityQ3en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster

info:eu-repo/semantics/openAccess
Aksi belirtilmediği sürece bu öğenin lisansı: info:eu-repo/semantics/openAccess