Basit öğe kaydını göster

dc.contributor.authorÇakal, Beytullah
dc.contributor.authorÇakal, Sinem
dc.contributor.authorKaraca, Oğuz
dc.contributor.authorKızılırmak Yılmaz, Filiz
dc.contributor.authorGüneş, Hacı Murat
dc.contributor.authorYıldırım, Arzu
dc.contributor.authorGüler, Yeliz
dc.contributor.authorÖzcan, Özgür Ulaş
dc.contributor.authorBoztosun, Bilal
dc.date.accessioned2023-02-22T11:31:01Z
dc.date.available2023-02-22T11:31:01Z
dc.date.issued2023en_US
dc.identifier.citationÇakal, B., Çakal, S., Karaca, O., Kızılırmak Yılmaz, F., Güneş, H. M., Yıldırım, A. ... Boztosun, B. (2023). How accurate are manufacturers' recommendations in determining ineligibility for transfemoral transcatheter aortic valve implantation? Revista Portuguesa de Cardiologia, 42(1), 31-38. https://doi.org/10.1016/j.repc.2021.09.019en_US
dc.identifier.issn0870-2551
dc.identifier.issn2174-2030
dc.identifier.urihttps://doi.org/10.1016/j.repc.2021.09.019
dc.identifier.urihttps://hdl.handle.net/20.500.12511/10504
dc.description.abstractIntroduction: Up to one-third of patients indicated for transcatheter aortic valve implantation (TAVI) may be unsuitable for transfemoral TAVI (TF-TAVI) according to manufacturers' recommendations and numerous professional societies. Objective: This study aimed to investigate the predictive value of manufacturers' guidelines for major vascular access site complications using the Perclose ProGlide device. Methods: Among 208 patients undergoing TF-TAVI, 144 patients (69.2%) were deemed eligible for TF-TAVI according to the manufacturer's instructions. A minimal lumen diameter (MLD) of the femoral artery below the manufacturer's specified limits and/or the presence of circumferential calcification were the reasons for ineligibility. Calcium score (CS), sheath-to-femoral artery ratio (SFAR) and MLD were estimated from computed tomography imaging. Vascular complications (VCs) (defined according to VARC-2 criteria) were retrospectively compared. Results: Patients in the ineligible group had higher SFAR (1.13±0.15 vs. 0.88±0.107, p<0.001) and CS (1.66±0.99 vs. 1.24±0.73; p=0.003), and significantly lower MLD (7.72±1.03 vs. 6.31±0.96 mm; p<0.001) compared to the eligible group. Major (6.3% vs. 12.3%, p=0.13) and minor VCs (10.4% vs. 15.6%, p=0.29) were similar in the eligible and ineligible groups. The ineligible group had higher rates of rupture (0.7% vs. 6.3%; p=0.03). SFAR was the only independent predictor of major VCs (OR 469.1, 95% CI 4.95-44466.57, p=0.008). Conclusion: The TAVI team should not decide whether the patient is suitable for a femoral approach based solely on the manufacturer's criteria, and should incorporate additional factors that could be predictive of major VCs.en_US
dc.language.isoengen_US
dc.publisherSociedade Portuguesa De Cardiologiaen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectAcesso Vascularen_US
dc.subjectAortic Valve Diseaseen_US
dc.subjectComplicationsen_US
dc.subjectComplicaçõesen_US
dc.subjectDoença Valvular Aórticaen_US
dc.titleHow accurate are manufacturers' recommendations in determining ineligibility for transfemoral transcatheter aortic valve implantation?en_US
dc.typearticleen_US
dc.relation.ispartofRevista Portuguesa de Cardiologiaen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Kardiyoloji Ana Bilim Dalıen_US
dc.authorid0000-0003-0230-6575en_US
dc.authorid0000-0003-2714-4584en_US
dc.authorid0000-0002-4281-0867en_US
dc.authorid0000-0003-1919-3183en_US
dc.authorid0000-0003-1516-1811en_US
dc.authorid0000-0002-4951-6716en_US
dc.authorid0000-0001-5825-8627en_US
dc.identifier.volume42en_US
dc.identifier.issue1en_US
dc.identifier.startpage31en_US
dc.identifier.endpage38en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.repc.2021.09.019en_US
dc.institutionauthorÇakal, Beytullah
dc.institutionauthorÇakal, Sinem
dc.institutionauthorKaraca, Oğuz
dc.institutionauthorKızılırmak Yılmaz, Filiz
dc.institutionauthorGüneş, Hacı Murat
dc.institutionauthorYıldırım, Arzu
dc.institutionauthorGüler, Yeliz
dc.institutionauthorÖzcan, Özgür Ulaş
dc.institutionauthorBoztosun, Bilal
dc.identifier.wosqualityQ4en_US
dc.identifier.wos000921413500001en_US
dc.identifier.scopus2-s2.0-85163456767en_US
dc.identifier.pmid36328866en_US
dc.identifier.scopusqualityQ3en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster

info:eu-repo/semantics/openAccess
Aksi belirtilmediği sürece bu öğenin lisansı: info:eu-repo/semantics/openAccess