Basit öğe kaydını göster

dc.contributor.authorKoyuncuoğlu, Cenker Zeki
dc.contributor.authorKara, Haluk Barış
dc.contributor.authorAkdemir, Sinan
dc.contributor.authorDemir, Becen
dc.contributor.authorHusain, Nadin Al-Haj
dc.contributor.authorÖzcan, Mutlu
dc.date.accessioned2021-02-25T07:48:39Z
dc.date.available2021-02-25T07:48:39Z
dc.date.issued2020en_US
dc.identifier.citationKoyuncuoğlu, C. Z., Kara, H. B., Akdemir, S., Demir, B., Husain, N. A. ve Özcan, M. (2020). Cleaning efficacy of poly-ether-ether-ketone tips in eliminating cement remnants around implants with different abutment heights. Journal of Oral Implantology, 46(6), 548-554. https://dx.doi.org/10.1563/aaid-joi-D-19-00095en_US
dc.identifier.issn0160-6972
dc.identifier.issn1548-1336
dc.identifier.urihttps://dx.doi.org/10.1563/aaid-joi-D-19-00095
dc.identifier.urihttps://hdl.handle.net/20.500.12511/6578
dc.description.abstractThe excess cement not removed after the cementation of fixed implant-supported restorations may cause loss of peri-implant attachment or adjacent bone. The aims of this study were to evaluate the amount of residual cement at different abutment-crown connection levels and to test the cleaning efficacy of poly-ether-ether-ketone (PEEK) ultrasonic tips after cementation. One implant was placed in an anterior central tooth position 5 mm below the gingival margin in an acrylic model, and 32 stone models were obtained with implant analogs. Abutment heights of 1-2 and 2.5-4 mm were used on the vestibular and lingual sides, respectively. Crowns were cemented and cleaned, and half of the samples were cleaned again using PEEK tips. The abutment-crown suprastructure was then disconnected, and cleaning efficacy was evaluated. Varying amounts of excess cement were found on all specimens except for the PEEK group with abutment-crown connections 1 mm below the gingival margin. An increase of undetected cement remnants was observed when the restoration margins were located deeper subgingivally. Various amounts of excess cement associated with margin location were detected on the abutment-restoration complex despite meticulous cleaning efforts. Ultrasonic PEEK tips were effective at cleaning the cement remnants around implants to a certain depth.en_US
dc.language.isoengen_US
dc.publisherAllen Press Incen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAbutment Heightsen_US
dc.subjectCleaning Methodsen_US
dc.subjectExcess Cementen_US
dc.subjectImplant Restorationsen_US
dc.subjectPEEKen_US
dc.titleCleaning efficacy of poly-ether-ether-ketone tips in eliminating cement remnants around implants with different abutment heightsen_US
dc.typearticleen_US
dc.relation.ispartofJournal of Oral Implantologyen_US
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi Ana Bilim Dalıen_US
dc.departmentİstanbul Medipol Üniversitesi, İMÜ Meslek Yüksekokulu, Diş Protez Teknolojisi Ana Bilim Dalıen_US
dc.authorid0000-0002-9292-2074en_US
dc.identifier.volume46en_US
dc.identifier.issue6en_US
dc.identifier.startpage548en_US
dc.identifier.endpage554en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1563/aaid-joi-D-19-00095en_US
dc.identifier.wosqualityQ4en_US
dc.identifier.scopusqualityQ3en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster