Basit öğe kaydını göster

dc.contributor.authorGündoğar, Mustafa
dc.contributor.authorÖzyürek, Taha
dc.contributor.authorYılmaz, Koray
dc.contributor.authorUslu, Gülşah
dc.date.accessioned2020-03-23T07:04:57Z
dc.date.available2020-03-23T07:04:57Z
dc.date.issued2019en_US
dc.identifier.citationGündoğar, M., Özyürek, M., Yılmaz, K. ve Uslu, G. (2017). Cyclic fatigue resistance of HyFlex EDM, Reciproc Blue, WaveOne Gold, and Twisted File Adaptive rotary files under different temperatures and ambient conditions. Journal of Dental Research Dental Clinics Dental Prospects, 13(3), 166-171. http://doi.org/10.15171/joddd.2019.026en_US
dc.identifier.urihttp://doi.org/10.15171/joddd.2019.026
dc.identifier.urihttps://hdl.handle.net/20.500.12511/5060
dc.description.abstractBackground. This study examined the effects of changes in temperature and environmental conditions on the cyclic fatigue resistance of Reciproc Blue, HyFlex EDM, WaveOne Gold, and Twisted File Adaptive. Methods. Forty-five Reciproc Blue (25/.08), 45 HyFlex EDM (25/.08), 45 WaveOne Gold (25/.07), and 45 Twisted File Adaptive (25/.08) files were tested for cyclic fatigue at room temperature (20°C) in air and water and at body temperature (35°C) in water. All the instruments were rotated in artificial canals made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius of curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds, using a digital chronometer. Mann-Whitney U test was used for the statistical analysis of data, with SPSS 21.0. Results. Cyclic fatigue resistance was significantly higher in all the groups in water at an ambient temperature of 20°C compared with air and water at temperatures of 20°C and 35°C, respectively (P<0.05). The intragroup analysis revealed that HyFlex EDM had the highest cyclic fatigue resistance, followed by Reciproc Blue, WaveOne Gold, and Twisted File Adaptive in both air and water at 20°C (P<0.05). HyFlex EDM exhibited the highest cyclic fatigue resistance in water at 35°C, whereas there was no significant difference between the other groups (P>0.05). Conclusion. Within the limitations of the present study, an increase in the ambient temperature significantly decreased the cyclic fatigue resistance of the tested NiTi files.en_US
dc.language.isoengen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCyclic Fatigueen_US
dc.subjectHyFlex EDMen_US
dc.subjectReciproc Blueen_US
dc.subjectStatic Testen_US
dc.subjectWaveOne Golden_US
dc.titleCyclic fatigue resistance of HyFlex EDM, Reciproc Blue, WaveOne gold, and twisted file adaptive rotary files under different temperatures and ambient conditionsen_US
dc.typearticleen_US
dc.relation.ispartofJournal of Dental Research Dental Clinics Dental Prospectsen_US
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Endodonti Ana Bilim Dalıen_US
dc.authorid0000-0001-8656-7101en_US
dc.identifier.volume13en_US
dc.identifier.issue3en_US
dc.identifier.startpage166en_US
dc.identifier.endpage171en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.15171/joddd.2019.026en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster