Seismic load tests on exterior beam-column connections of existing RC structures
View/ Open
Access
info:eu-repo/semantics/openAccessDate
2019Author
Coşgun, TurgayCoşgun, Cumhur
Kaniskha, Abdulrauf
Mangır, Atakan
Sayın, Barış
Türk, Ahmet Murat
Metadata
Show full item recordCitation
Coşgun, T., Coşgun, C., Kanishka, A., Mangır, A., Sayın, B. ve Türk, A. M. (2019). Seismic load tests on exterior beam-column connections of existing RC structures. Gradevinar, 71(12), 1129-1141. https://doi.org/10.14256/JCE.2524.2018Abstract
Recommendations for enhancement of performance of RC beam-column joints under seismic effects are presented in this study. The aim is to evaluate the use of low-strength concrete with plain bars without stirrups in the joints. An additional aim is to study behaviour of joints in the aforementioned conditions under cyclic loading. Five specimens with various reinforcement configurations were produced and tested in the experimental process. Based on results obtained in the study, it is concluded that the stirrup arrangement in the joints, and the use of at least 90-degree hooks in longitudinal reinforcement of beams, are critical parameters for the performance of existing structures. U radu su izneseni prijedlozi za poboljšanje svojstava spojeva greda-stup postojećih AB konstrukcija uslijed potresnog djelovanja. Analizirana je uporaba betona niske čvrstoće, glatkog armaturnog čelika bez spona u spojevima te je ispitano ponašanje spojeva u uvjetima pod cikličnim opterećenjem. U okviru eksperimentalnog istraživanja proizvedeno je i ispitano pet uzoraka s različitim rasporedom armature. Na temelju rezultata zaključeno je da su kritični parametri koji određuju svojstva postojećih konstrukcija, raspored spona u spojevima i upotreba kuka za sidrenje uzdužne armature koje su savijene pod kutom od najmanje 90°. In dieser Studie werden Vorschläge zur Verbesserung der Eigenschaften von StahlbetonBalken-Pfeilerverbindungen infolge von Erdbebeneinwirkung gemacht. Ziel ist es, die Verwendung von glattem Stahlbeton einer geringen Festigkeit ohne Spanner in den Verbindungen zu bewerten. Es ist auch beabsichtigt, das Verhalten der Verbindungen unter Bedingungen unter zyklischer Belastung zu untersuchen. Im experimentellen Verfahren wurden fünf Proben mit unterschiedlicher Anordnung der Bewehrung hergestellt und geprüft. Aufgrund der Ergebnisse wird der Schluss gezogen, dass die Anordnung der Spanner in den Verbindungen und die Verwendung von Haken unter einer mindestens 900-Längsbewehrung kritische Parameter für die Bestimmung der Eigenschaften bestehender Konstruktionen sind.
WoS Q Kategorisi
Q4Source
GradevinarVolume
71Issue
12Collections
- Makale Koleksiyonu [98]
- WoS İndeksli Yayınlar Koleksiyonu [6417]