dc.identifier.citationBaşkan, Ö., Erol, C., Özbek, H. ve Paksoy, Y. (2015). Effect of radiation dose reduction on image quality in adult head CT with noise-suppressing reconstruction system with a 256 slice MDCT. Journal of Applied Clinical Medical Physics, 16(3), 285-296. https://dx.doi.org/10.1120/jacmp.v16i3.5360en_US
dc.identifier.issn1526-9914
dc.identifier.urihttps://dx.doi.org/10.1120/jacmp.v16i3.5360
dc.identifier.urihttps://hdl.handle.net/20.500.12511/2952
dc.descriptionWOS: 000354950100028en_US
dc.descriptionPubMed ID: 26103494en_US
dc.description.abstractThe purpose of our study was to investigate the effect of iterative reconstruction (IR) as a dose reduction system on the image quality (IQ) of the adult head computed tomography (CT) at various low-dose levels, and to identify ways of setting the amount of dose reduction. We performed two noncontrast low-dose (LD) adult head CT protocols modified by lowering the tube current with IR which were decided in the light of a group of phantom studies. Two groups of patients, each 100 underwent noncontrast head CT with LD-I and LD-II, respectively. These groups were compared with 100 consecutive standard dose (STD) adult head CT protocol in terms of quantitative and qualitative IQ. The signal-to-noise ratio (SNR) of the white matter (WM) and gray matter (GM) and contrast-to-noise ratio (CNR) values in the LD groups were higher than the STD group. The differences were statistically significant. When the STD and the LD groups were compared qualitatively, no significant differences were found in overall quality. By selecting the appropriate level of IR 34%, radiation dose reduction in adult head CT can be achieved without compromising IQ.en_US
dc.language.isoengen_US
dc.publisherMultimeden_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectImage Qualityen_US
dc.subjectDose Reductionen_US
dc.subjectReconstruction Methodsen_US
dc.subjectPhantom Studiesen_US
dc.subjectMDCTen_US
dc.titleEffect of radiation dose reduction on image quality in adult head CT with noise-suppressing reconstruction system with a 256 slice MDCTen_US
dc.typearticleen_US
dc.relation.ispartofJournal of Applied Clinical Medical Physicsen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Radyoloji Ana Bilim Dalıen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Tıbbi Farmakoloji Ana Bilim Dalıen_US
dc.authorid0000-0003-3468-7712en_US
dc.authorid0000-0002-8084-7855en_US
dc.identifier.volume16en_US
dc.identifier.issue3en_US
dc.identifier.startpage285en_US
dc.identifier.endpage296en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1120/jacmp.v16i3.5360en_US
dc.identifier.wosqualityQ3en_US
dc.identifier.scopusqualityQ1en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster