Basit öğe kaydını göster

dc.contributor.authorTorun Acar, Banu
dc.contributor.authorMüftüoğlu, Orkun
dc.contributor.authorAcar, Suphi
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:51:36Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:51:36Z
dc.date.issued2014en_US
dc.identifier.citationTorun Acar, B., Müftüoğlu, O. ve Acar, S. (2014). Comparison of sulfur hexafluoride and air for donor attachment in descemet stripping endothelial keratoplasty in patients with pseudophakic bullous keratopathy. Cornea, 33(3), 219-222. https://dx.doi.org/10.1097/ICO.0000000000000049en_US
dc.identifier.issn0277-3740
dc.identifier.issn1536-4798
dc.identifier.urihttps://dx.doi.org/10.1097/ICO.0000000000000049
dc.identifier.urihttps://hdl.handle.net/20.500.12511/2247
dc.descriptionWOS: 000331530700001en_US
dc.descriptionPubMed ID: 24452211en_US
dc.description.abstractPurpose:The aim of this study was to evaluate the clinical efficacy and safety of sulfur hexafluoride (SF6) as a tamponading agent after donor placement during Descemet stripping endothelial keratoplasty (DSEK) surgery and to compare the outcomes with those of air.Methods:Forty-four eyes of 44 consecutive patients who underwent DSEK were included in the study. Air was used in 22 eyes of 22 patients (air group), and SF6 was used in 22 eyes of 22 patients (SF6 group) to attach the donor lenticule. The complications, corrected visual acuity (CVA), and the endothelial cell density (ECD) results were compared between these 2 groups.Results:Six eyes had graft dislocation in the air group that underwent successful rebubbling on postoperative day 1. There was no graft dislocation in the SF6 group. There was no other complication observed in both the groups. The mean increase in the CVA was 1.09 0.36 logarithm of the minimum angle of resolution in the air group, whereas it was 0.80 +/- 0.57 logarithm of the minimum angle of resolution in the SF6 group. The mean increase in the CVA was not statistically different between the 2 groups (P = 0.060). Compared with the mean ECD in donor grafts, the mean decrease in the ECD was 222 +/- 86 (44%) cells per square millimeter in the air group and 178 +/- 52 (39%) cells per square millimeter in the SF6 group at the 1-year follow-up. The mean decrease in the ECD was statistically significantly higher in the air group compared with that in the SF6 group (P = 0.049).Conclusions:SF6 is comparable to air for attaching the donor graft as a tamponading agent in DSEK surgery.en_US
dc.language.isoengen_US
dc.publisherLippincott Williams & Wilkinsen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectDescemet Stripping Endothelial Keratoplastyen_US
dc.subjectSulfur Hexafluorideen_US
dc.subjectEndothelial Cell Densityen_US
dc.titleComparison of sulfur hexafluoride and air for donor attachment in descemet stripping endothelial keratoplasty in patients with pseudophakic bullous keratopathyen_US
dc.typearticleen_US
dc.relation.ispartofCorneaen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalıen_US
dc.identifier.volume33en_US
dc.identifier.issue3en_US
dc.identifier.startpage219en_US
dc.identifier.endpage222en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1097/ICO.0000000000000049en_US
dc.identifier.wosqualityQ3en_US
dc.identifier.scopusqualityQ1en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster