Basit öğe kaydını göster

dc.contributor.authorÖzyürek, Taha
dc.contributor.authorGündoğar, Mustafa
dc.contributor.authorUslu, Gülşah
dc.contributor.authorYılmaz, Koray
dc.contributor.authorStaffoli, Simone
dc.contributor.authorGrande, N. M.
dc.contributor.authorPlotino, Gianluca
dc.contributor.authorPolimeni, Antonella
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:50:09Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:50:09Z
dc.date.issued2018en_US
dc.identifier.citationÖzyürek, T., Gündoğar, M., Uslu, G., Yılmaz, K., Staffoli, S., Grande, N. M. ... Polimeni, A. (2018). Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals. Odontology, 106(4), 408-413. https://dx.doi.org/10.1007/s10266-018-0340-yen_US
dc.identifier.issn1618-1247
dc.identifier.issn1618-1255
dc.identifier.urihttps://dx.doi.org/10.1007/s10266-018-0340-y
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1897
dc.descriptionWOS: 000444954600007en_US
dc.descriptionPubMed ID: 29383604en_US
dc.description.abstractThe aim of the present study was to compare the cyclic fatigue resistances of HyFlex EDM (HEDM), WaveOne Gold (WOG), Reciproc Blue (RB), and 2Shape (TS) NiTi systems having different metallurgic properties. HEDM, WOG, RB, and TS instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5mm, 45 degrees, and 90 degrees angles of curvatures and a radius of curvature of 5mm until fracture occurred, and the time to fracture (TTF) was recorded in seconds. Also, number of cycles to fracture was calculated (NCF). Data were statistically analyzed using Kruskal-Wallis and t test. The statistical significance level was set at P<0.05. When comparing the TTF of all the instruments tested in the artificial canal with 45 degrees curvature, RB had statistically the highest cyclic fatigue resistance followed by HEDM and TS (P<0.05), while the WOG showed the lowest cyclic fatigue resistance (P<0.05). In artificial canal with 90 degrees curvature, RB showed a significantly higher cyclic fatigue resistance than the other tested files (P<0.05), while there was no significant difference among the TS, WOG and HEDM groups (P>0.05). When the NCF values were taken into consideration, HEDM reported a significantly higher cyclic fatigue resistance than TS in both canal curvatures analyzed (P<0.05). Within the limitations of the present study, RB NiTi files showed statistically higher cyclic fatigue resistance in artificial canals with 45 degrees and 90 degrees than the other NiTi files tested.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectCyclic Fatigueen_US
dc.subjectHyFlex EDMen_US
dc.subjectWaveOne Golden_US
dc.subjectReciproc Blueen_US
dc.subject2Shapeen_US
dc.titleCyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canalsen_US
dc.typearticleen_US
dc.relation.ispartofOdontologyen_US
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Endodonti Ana Bilim Dalıen_US
dc.authorid0000-0001-8656-7101en_US
dc.identifier.volume106en_US
dc.identifier.issue4en_US
dc.identifier.startpage408en_US
dc.identifier.endpage413en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1007/s10266-018-0340-yen_US
dc.identifier.wosqualityQ2en_US
dc.identifier.scopusqualityQ2en_US