dc.description.abstractObjectivesThe aim of the study was to evaluate and compare the radiopacity of 20 current dental resin composites with digital radiography.MethodsTen specimens, 10-mm in diameter and 1-mm thickness, were prepared and radiographed using phosphor plates close to Al step wedges and tooth sections. The mean grey values (MGVs) were measured using an ImageJ software program and converted to equivalent Al thickness. Data were analyzed using one-way analysis of variance (ANOVA) and Tamhane post hoc test (p < 0.05). Correlation between mean radiopacity and filler content (wt% and vol%) of the tested materials was analyzed with linear regression analysis.ResultsThe radiopacity of all composites ranged from 1.32 mm Al (Estellite Flow Quick) to 3.41 mm Al (Charisma Classic). All the tested materials, except four restorative materials, had a radiopacity equal or higher than the enamel (p < 0.05). Linear regression revealed low correlation between the radiopacity and filler content of the composite.ConclusionMajority of the materials has appropriate radiopacity for dental restorations. There was great variation in radiopacity level, may clinically affect the diagnosis.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectAluminum Step Wedgeen_US
dc.subjectDigital Radiographyen_US
dc.subjectRadiopacityen_US
dc.subjectResin Compositesen_US
dc.titleRadiopacity evaluation of different types of resin restorative materials using a digital radiography systemen_US
dc.typearticleen_US
dc.relation.ispartofOral Radiologyen_US
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Restoratif Diş Tedavisi Ana Bilim Dalıen_US
dc.authorid0000-0002-5158-3379en_US
dc.identifier.volume39en_US
dc.identifier.issue4en_US
dc.identifier.startpage646en_US
dc.identifier.endpage653en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1007/s11282-023-00679-6en_US
dc.institutionauthorGündoğdu, Ceyda
dc.identifier.wosqualityQ3en_US
dc.identifier.wos000950090900001en_US
dc.identifier.scopus2-s2.0-85149905642en_US
dc.identifier.pmid36920599en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster