Basit öğe kaydını göster

dc.contributor.authorSezer, Salim
dc.contributor.authorOğlak, Süleyman Cemil
dc.contributor.authorKaya, Başak
dc.contributor.authorBehram, Mustafa
dc.contributor.authorGedik Özköse, Zeynep
dc.contributor.authorSüzen Çaypınar, Sema
dc.contributor.authorAcar, Züat
dc.contributor.authorGezdirici, Alper
dc.contributor.authorBornaun, Helen
dc.date.accessioned2023-05-31T10:49:44Z
dc.date.available2023-05-31T10:49:44Z
dc.date.issued2023en_US
dc.identifier.citationSezer, S., Oğlak, S. C., Kaya, B., Behram, M., Gedik Özköse, Z., Süzen Çaypınar, S. ... Bornaun, H. (2023). Fetal left ventricular myocardial performance index measured at 11–14 weeks of gestation in fetuses with an increased nuchal translucency. Journal of Obstetrics and Gynaecology Research, 49(4), 1121-1128. https://doi.org/10.1111/jog.15551en_US
dc.identifier.issn1341-8076
dc.identifier.issn1447-0756
dc.identifier.urihttps://doi.org/10.1111/jog.15551
dc.identifier.urihttps://hdl.handle.net/20.500.12511/11002
dc.description.abstractObjective: This study aimed to evaluate the effect of an increase in nuchal translucency (NT) thickness on the myocardial performance index (MPI) in fetuses without cardiac anomaly in the first trimester and to determine whether a difference in MPI between those with and without trisomy 21 in these fetuses could be determined. Methods: The study group consisted of 53 pregnancies complicated with increased NT thickness without any associated structural anomalies. Forty-six gestational age-matched pregnant women whose fetuses had normal NT thickness were enrolled as the control group. Results: In the increased NT thickness group, the mean isovolumetric relaxation time (IRT) value (0.050 ± 0.011 s) was significantly higher and the mean ejection time (ET) value (0.149 ± 0.010 s) was significantly lower than those values in the normal NT thickness group (0.045 ± 0.005 and 0.155 ± 0.009 s, p = 0.023 and p = 0.009, respectively). We found a significantly higher mean left MPI value in the increased NT thickness group (0.574 ± 0.153) versus the normal NT thickness group (0.487 ± 0.107, p < 0.001). Within the increased NT thickness group, the mean left MPI value was similar in the fetuses with normal karyotype and those with trisomy 21 (p = 0.419). Conclusion: We demonstrated a significantly greater mean MPI value in the increased NT thickness group than in the normal NT thickness group. Within the increased NT thickness group, no differences in the left MPI value in the fetuses with normal karyotype and the fetuses with trisomy 21 were found.en_US
dc.language.isoengen_US
dc.publisherWileyen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectDoppler-Diagnosticen_US
dc.subjectObstetricsen_US
dc.subjectDiagnostic Ultrasound and Prenatal Diagnosisen_US
dc.titleFetal left ventricular myocardial performance index measured at 11–14 weeks of gestation in fetuses with an increased nuchal translucencyen_US
dc.typearticleen_US
dc.relation.ispartofJournal of Obstetrics and Gynaecology Researchen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Kadın Hastalıkları ve Doğum Ana Bilim Dalıen_US
dc.authorid0000-0002-2257-2355en_US
dc.identifier.volume49en_US
dc.identifier.issue4en_US
dc.identifier.startpage1121en_US
dc.identifier.endpage1128en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1111/jog.15551en_US
dc.institutionauthorKaya, Başak
dc.identifier.wosqualityQ4en_US
dc.identifier.wos000921641000001en_US
dc.identifier.scopus2-s2.0-85146923216en_US
dc.identifier.pmid36691372en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster