Basit öğe kaydını göster

dc.contributor.authorAkman, Mustafa
dc.date.accessioned2023-02-13T08:38:24Z
dc.date.available2023-02-13T08:38:24Z
dc.date.issued2023en_US
dc.identifier.citationAkman, M. (2023). Is it reliable to make a decision based on visual changes in the patient's diaper in the evaluation of post circumcision bleeding? African Journal of Paediatric Surgery : AJPS, 20(1), 12-20. https://dx.doi.org/10.4103/ajps.ajps_157_21en_US
dc.identifier.issn0974-5998
dc.identifier.issn0189-6725
dc.identifier.urihttps://dx.doi.org/10.4103/ajps.ajps_157_21
dc.identifier.urihttps://hdl.handle.net/20.500.12511/10423
dc.description.abstractBackground: The most common complication of circumcision is bleeding. Monitoring bleeding by visual assessment of the diaper can cause errors due to the high absorbency of diapers. The patient may have had significant problems before the visible changes. The amount of liquid that wets the cloth does not necessarily lead to a visual change consistent with the amount, and the nature of the liquid contaminating the diaper may cause difficulties in terms of visual evaluation. Making a decision based on the visual changes in the patient's diaper cannot be considered as reliable. Methods: We planned to evaluate the visual changes that are caused by liquids of various volumes and contents that wet the diaper, according to measurable criteria. We aimed to emphasise the importance of the subject in circumcision practices of diapered children. Wetting of diapers with different volumes and variable blood load was performed utilising blood with different haematocrits and fluids. One hundred and sixty different diapers in four groups were moistened utilising the drip method. Visual changes in the soaked diapers were evaluated with the colorimetric method and five different colour criteria. The saturation and lightness values, which indicate the colour value, were obtained by using the numerical equivalents of the three main components, red, green and blue. Analysis was carried out by subjecting statistical evaluation within and between groups. Results: There was a significant difference between the control group and the study group. It was observed that visual changes caused by the moistened cloths with linear increase did not make the same linear interaction. There was not a significant difference between Group II and Group IV, which were soaked with the same amount of blood and different volume of fluid. In Group III, colour saturation changes were found to have a parabolic effect instead of a linear change. In two different analyses of moistened diapers in terms of volume and blood load; it was not determined that the expected linear changes between the groups were not observed. Conclusion: Visual changes in diapers related to volume or blood load effects of fluids may not be compatible with the amount of bleeding. Mistakes may occur when super absorbent wipes are used when determining the amount of bleeding from the use of colour changes in the diaper. Visual changes should not be relied on in bleeding due to circumcision. Rather, vital signs follow-up and measurable laboratory tests should be used as a basis.en_US
dc.language.isoengen_US
dc.publisherNLM (Medline)en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectBleedingen_US
dc.subjectCircumcisionen_US
dc.subjectComplicationsen_US
dc.titleIs it reliable to make a decision based on visual changes in the patient's diaper in the evaluation of post circumcision bleeding?en_US
dc.typearticleen_US
dc.relation.ispartofAfrican Journal of Paediatric Surgery : AJPSen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Çocuk Cerrahisi Ana Bilim Dalıen_US
dc.authorid0000-0002-6789-4585en_US
dc.identifier.volume20en_US
dc.identifier.issue1en_US
dc.identifier.startpage12en_US
dc.identifier.endpage20en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.4103/ajps.ajps_157_21en_US
dc.institutionauthorAkman, Mustafa
dc.identifier.scopus2-s2.0-85147187079en_US
dc.identifier.pmid36722564en_US
dc.identifier.scopusqualityQ4en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster

info:eu-repo/semantics/openAccess
Aksi belirtilmediği sürece bu öğenin lisansı: info:eu-repo/semantics/openAccess