Basit öğe kaydını göster

dc.contributor.authorKandemir Beşek, Nilay
dc.contributor.authorAşık Nacaroğlu, Şenay
dc.contributor.authorKırgız, Ahmet
dc.contributor.authorÖztürk Karabulut, Gamze
dc.contributor.authorÖkmen, Helin
dc.contributor.authorAhmet, Sibel
dc.date.accessioned2023-01-13T07:55:07Z
dc.date.available2023-01-13T07:55:07Z
dc.date.issued2023en_US
dc.identifier.citationKandemir Beşek, N., Aşık Nacaroğlu, Ş., Kırgız, A., Öztürk Karabulut, G., Ökmen, H. ve Ahmet, S. (2023). Efficacy of keratometric values obtained from Sirius topographer® in nidek axial length-scan® for intraocular lens calculation after penetrating keratoplasty. Photodiagnosis and Photodynamic Therapy, 41. https://dx.doi.org/10.1016/j.pdpdt.2022.103195en_US
dc.identifier.issn1572-1000
dc.identifier.issn1873-1597
dc.identifier.urihttps://dx.doi.org/10.1016/j.pdpdt.2022.103195
dc.identifier.urihttps://hdl.handle.net/20.500.12511/10302
dc.description.abstractBackground: To evaluate the accuracy of keratometric values obtained from Scheimpflug (Sirius) topography using Nidek AL-Scan optical biometry (OB) for intraocular lens (IOL) power calculating after penetrating keratoplasty (PK). Methods: Thirty eyes of 26 patients were included in this study. The demographic information, complete ophthalmic examination, IOL calculation technique, and its effect on final refractive results were evaluated. Results: The mean age of the patients was 52.76 ± 16.20 years. The mean K readings using Nidek AL-Scan OB, mean simulated K (SimK) (3mm), and mean pupillary power (MPP) (4.5mm) K readings using Sirius were 41.92 ± 5.05 D, 42.99 ± 5.78 D, and 43.30±6.23 D (p= 0.515). Conclusions: Both devices correctly calculated IOL power after PK; however, Sirius SimK (3mm) gave the lowest mean absolute error (MAE) results and can be safely used for IOL power calculation.en_US
dc.language.isoengen_US
dc.publisherElsevier B.V.en_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectCataract Surgeryen_US
dc.subjectOptical Biometryen_US
dc.subjectPenetrating Keratoplastyen_US
dc.subjectScheimpflug Topographyen_US
dc.titleEfficacy of keratometric values obtained from Sirius topographer® in nidek axial length-scan® for intraocular lens calculation after penetrating keratoplastyen_US
dc.title.alternativeEfficacy of keratometric values obtained from Sirius topographer (R) in nidek axial length-scan (R) for intraocular lens calculation after penetrating keratoplastyen_US
dc.typearticleen_US
dc.relation.ispartofPhotodiagnosis and Photodynamic Therapyen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalıen_US
dc.identifier.volume41en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.pdpdt.2022.103195en_US
dc.institutionauthorAşık Nacaroğlu, Şenay
dc.identifier.wosqualityQ3en_US
dc.identifier.wos000990736500001en_US
dc.identifier.scopus2-s2.0-85145747196en_US
dc.identifier.pmid36379304en_US
dc.identifier.scopusqualityQ2en_US