dc.contributor.author | Çakal, Beytullah | |
dc.contributor.author | Çakal, Sinem | |
dc.contributor.author | Karaca, Oğuz | |
dc.contributor.author | Kızılırmak Yılmaz, Filiz | |
dc.contributor.author | Güneş, Hacı Murat | |
dc.contributor.author | Yıldırım, Arzu | |
dc.contributor.author | Özcan, Özgür Ulaş | |
dc.contributor.author | Güler, Yeliz | |
dc.contributor.author | Boztosun, Bilal | |
dc.date.accessioned | 2022-12-26T09:38:14Z | |
dc.date.available | 2022-12-26T09:38:14Z | |
dc.date.issued | 2022 | en_US |
dc.identifier.citation | Çakal, B., Çakal, S., Karaca, O., Kızılırmak Yılmaz, F., Güneş, H. M., Yıldırım, A. ... Boztosun, B. (2022). Angio-seal used as a bailout for incomplete hemostasis after dual perclose ProGlide deployment in transcatheter aortic valve implantation. Texas Heart Institute Journal, 49(6). https://doi.org/10.14503/THIJ-21-7684 | en_US |
dc.identifier.issn | 0730-2347 | |
dc.identifier.uri | https://doi.org/10.14503/THIJ-21-7684 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12511/10183 | |
dc.description.abstract | Background: The failure rate of vascular closure devices remains a significant cause of major vascular complications in contemporary transcatheter aortic valve implantation practice. Methods: This research aimed to evaluate use of the Angio-Seal device in a bailout context in the setting of incomplete hemostasis following use of dual Perclose ProGlide devices in patients undergoing transfemoral transcatheter aortic valve implantation. A total of 185 patients undergoing transfemoral transcatheter aortic valve implantation with either dual Per-close ProGlide (n = 139) or a combination of dual Perclose ProGlide and Angio-Seal (n = 46) were retrospectively analyzed. The baseline, procedural characteristics, and all outcomes (defined according to Valve Academic Research Consortium-2 criteria) were compared. Results: No significant differences were seen between the dual Perclose ProGlide vs dual Perclose ProGlide+Angio-Seal groups with regard to the in-hospital Valve Academic Research Consortium-2 primary end points of major vascular complications (n = 13 [9.4%] vs n = 2 [4.3%]; P =.36), minor vascular complications (n = 13 [9.4%] vs n = 8 [14.7%]; P =.14), major bleeding (n = 16 [11.5%] vs n = 2 [4.3%]; P =.25), and minor bleeding (n = 9 [6.5%] vs n = 5 [10.9%]; P =.34), with higher rates of hematoma in the dual Perclose ProGlide+Angio-Seal group (n = 4 [2.9%] vs n = 5 [10.9%]; P =.044). Conclusion: Finding from the current study suggest that adjunctive Angio-Seal deployment may be feasible and safe, especially in patients with incomplete hemostasis following dual Perclose ProGlide use, and can be an optimal “bailout” procedure. (Tex Heart Inst J. 2022;49(6):e217684). | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Texas Heart Institute | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Peripheral Artery Diseases | en_US |
dc.subject | Hemostasis | en_US |
dc.subject | Vascular Access Device | en_US |
dc.title | Angio-seal used as a bailout for incomplete hemostasis after dual perclose ProGlide deployment in transcatheter aortic valve implantation | en_US |
dc.type | article | en_US |
dc.relation.ispartof | Texas Heart Institute Journal | en_US |
dc.department | İstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Kardiyoloji Ana Bilim Dalı | en_US |
dc.authorid | 0000-0003-0230-6575 | en_US |
dc.authorid | 0000-0002-4281-0867 | en_US |
dc.authorid | 0000-0003-1919-3183 | en_US |
dc.authorid | 0000-0001-5825-8627 | en_US |
dc.authorid | 0000-0003-1516-1811 | en_US |
dc.authorid | 0000-0002-4951-6716 | en_US |
dc.identifier.volume | 49 | en_US |
dc.identifier.issue | 6 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.14503/THIJ-21-7684 | en_US |
dc.institutionauthor | Çakal, Beytullah | |
dc.institutionauthor | Karaca, Oğuz | |
dc.institutionauthor | Kızılırmak Yılmaz, Filiz | |
dc.institutionauthor | Güneş, Hacı Murat | |
dc.institutionauthor | Yıldırım, Arzu | |
dc.institutionauthor | Özcan, Özgür Ulaş | |
dc.institutionauthor | Güler, Yeliz | |
dc.institutionauthor | Boztosun, Bilal | |
dc.identifier.wosquality | Q4 | en_US |
dc.identifier.wos | 000899359200001 | en_US |
dc.identifier.scopus | 2-s2.0-85144066677 | en_US |
dc.identifier.pmid | 36515932 | en_US |
dc.identifier.scopusquality | Q3 | en_US |