Basit öğe kaydını göster

dc.contributor.authorÇevik Saldıran, Tülay
dc.contributor.authorKara, İlke
dc.contributor.authorKutlutürk Yıkılmaz, Seval
dc.date.accessioned2022-11-04T08:06:25Z
dc.date.available2022-11-04T08:06:25Z
dc.date.issued2022en_US
dc.identifier.citationÇevik Saldıran, T., Kara, İ. ve Kutlutürk Yıkılmaz, S. (2022). Quantification of the forearm muscles mechanical properties using Myotonometer: Intra- and Inter-Examiner reliability and its relation with hand grip strength. Journal of Electromyography and Kinesiology, 67. https://doi.org/10.1016/j.jelekin.2022.102718en_US
dc.identifier.issn1050-6411
dc.identifier.issn1873-5711
dc.identifier.urihttps://doi.org/10.1016/j.jelekin.2022.102718
dc.identifier.urihttps://hdl.handle.net/20.500.12511/9921
dc.description.abstractThe primary objective of this study was to investigate the reliability of the myotonometer in the mechanical properties of the forearm muscles [m. extensor carpi radialis brevis (ECRB), and m. flexor carpi ulnaris (FCU)] in healthy individuals. The secondary objective was to investigate the relationship between the handgrip strength and mechanical properties of these forearm muscles. The mechanical properties (muscle tone, stiffness, and elasticity) of the ECRB and FCU were measured using the MyotonPRO device. Examiner 1 performed two sets of measurements with a time interval of 30 min to determine intra-examiner reliability. Examiner 2 performed measurements during the interval between the two sets of examiner 1. The intra- and inter-examiner reliabilities were excellent (ICC˃0.82) for muscle tone, stiffness, and elasticity of the FCU. Both intra- and inter-examiner reliability in the evaluation of ECRB muscle tone, elasticity, and stiffness was moderate to excellent (ICCs = 0.56–0.98). The muscle tone and stiffness properties of the FCU were positively correlated with the handgrip strength (p <.05). The study findings indicate that the MyotonPRO device is a reliable tool to quantify ECRB, and FCU muscles mechanical properties in healthy individuals.en_US
dc.language.isoengen_US
dc.publisherElsevier Ltden_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectBiomechanicsen_US
dc.subjectPhysiotherapyen_US
dc.subjectReliability Studyen_US
dc.subjectSkeletal Muscleen_US
dc.subjectStrengthen_US
dc.titleQuantification of the forearm muscles mechanical properties using Myotonometer: Intra- and Inter-Examiner reliability and its relation with hand grip strengthen_US
dc.typearticleen_US
dc.relation.ispartofJournal of Electromyography and Kinesiologyen_US
dc.departmentİstanbul Medipol Üniversitesi, Sağlık Bilimleri Fakültesi, Fizyoterapi ve Rehabilitasyon Bölümüen_US
dc.authorid0000-0001-9120-7071en_US
dc.identifier.volume67en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.jelekin.2022.102718en_US
dc.institutionauthorKutlutürk Yıkılmaz, Seval
dc.identifier.wosqualityQ2en_US
dc.identifier.wos000880050400002en_US
dc.identifier.scopus2-s2.0-85140615646en_US
dc.identifier.pmid36334405en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster