• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   [email protected]
  • Fakülteler
  • Tıp Fakültesi
  • Makale Koleksiyonu
  • View Item
  •   [email protected]
  • Fakülteler
  • Tıp Fakültesi
  • Makale Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Dosimetric comparison of robotic- and LINAC-based treatment of spine stereotactic body radiotherapy

Thumbnail

View/Open

Tam Metin / Full Text (1.359Mb)

Access

info:eu-repo/semantics/embargoedAccess

Date

2022

Author

Acar, Hilal
Yazıcı, Ömer
Ünal, Dilek

Metadata

Show full item record

Citation

Acar, H., Yazıcı, Ö. ve Ünal, D. (2022). Dosimetric comparison of robotic- and LINAC-based treatment of spine stereotactic body radiotherapy. Medical Dosimetry, 47(4), 348-355. https://doi.org/10.1016/j.meddos.2022.08.002

Abstract

To determine which treatment technique and modality would offer better dosimetric results and be preferable for spinal stereotactic body therapy (SBRT) depending on the three different regions of the vertebrae. Linear accelerator (LINAC)- and CyberKnife (CK)-based treatment techniques were compared in terms of their dosimetric quality, treatment efficiency, and delivery accuracy. Thirty previously treated patients were included in this study. Intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques were used for LINAC-based treatment, whereas CK-based treatment plans were generated for two different collimator systems: fixed and multileaf collimator (MLC). The plans were compared based on spinal cord sparing, dose homogeneity, conformity index (CI), gradient index (GI), monitor unit (MU), and beam-on time. The percentage volumes of V2Gy, V5Gy (representing volume low of the dose spillage region), V10Gy, and V20Gy (representing the volume of the high-dose spillage region) of the healthy tissue were analyzed. The CI and GI of the VMAT plans were better than those of the IMRT plans. For spinal cord sparing, the VMAT and MLC-based CK (CK-MLC) techniques were superior. The percentage of low-dose spillage regions was the lowest for IMRT and fixed cone-based CK (CK-FIX) plans. The percentage of the high-dose spillage region was the lowest for the VMAT and CK-MLC plans. In terms of treatment efficiency, the VMAT and CK-MLC plans were superior to the IMRT and CK-FIX plans. The VMAT technique lowered the MU and beam-on time values. The plan delivery accuracy of the VMAT and CK-FIX plans was better than that of the IMRT plans. VMAT is the best option for LINAC-based spinal SBRT. For CK-based spinal SBRT, MLC-based plans are preferred. If the clinic has both treatment modalities and the patient can tolerate long treatment times, CK-MLC-based treatment should be chosen because of its superiority in sparing the spinal cord and sharp dose fall-off.

WoS Q Kategorisi

Q4

xmlui.dri2xhtml.METS-1.0.item-scopusquality

Q3

Source

Medical Dosimetry

Volume

47

Issue

4

URI

https://doi.org/10.1016/j.meddos.2022.08.002
https://hdl.handle.net/20.500.12511/9892

Collections

  • Makale Koleksiyonu [3163]
  • PubMed İndeksli Yayınlar Koleksiyonu [3481]
  • Scopus İndeksli Yayınlar Koleksiyonu [5318]
  • WoS İndeksli Yayınlar Koleksiyonu [5543]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Guide | Contact |

[email protected]

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsInstitution AuthorORCIDTitlesSubjectsTypeLanguageDepartmentCategoryWoS Q ValueScopus Q ValuePublisherAccess TypeThis CollectionBy Issue DateAuthorsInstitution AuthorORCIDTitlesSubjectsTypeLanguageDepartmentCategoryWoS Q ValueScopus Q ValuePublisherAccess Type

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide || Library || İstanbul Medipol University || OAI-PMH ||

Kütüphane ve Dokümantasyon Daire Başkanlığı, İstabul, Turkey
If you find any errors in content, please contact: [email protected]

Creative Commons License
[email protected] by İstanbul Medipol University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

[email protected]:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.