Basit öğe kaydını göster

dc.contributor.authorTüfekçioğlu, Şükran
dc.contributor.authorDelilbaşı, Barış Çağrı
dc.contributor.authorGürler, Gökhan
dc.contributor.authorDilaver, Emrah
dc.contributor.authorÖzer, Naci
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:35:50Z
dc.date.available10.07.201910:49:14
dc.date.available2019-07-10T19:35:50Z
dc.date.issued2017en_US
dc.identifier.citationTüfekçioğlu, Ş., Delilbaşı, B. Ç., Gürler, G., Dilaver, E. ve Özer, N. (2017). Is 2 mm a safe distance from the inferior alveolar canal to avoid neurosensory complications in implant surgery? Nigerian Journal of Clinical Practice, 20(3), 274-277. https://dx.doi.org/10.4103/1119-3077.183240en_US
dc.identifier.issn1119-3077
dc.identifier.urihttps://hdl.handle.net/20.500.12511/959
dc.identifier.urihttps://dx.doi.org/10.4103/1119-3077.183240
dc.description.abstractAim: The aim of the present study was to compare the neurosensory complications related to implants inserted closer than 2 mm to the inferior alveolar canal (IAC) with those inserted further than 2 mm. Materials and Methods: A total of 474 implants in 314 patients placed posterior to mental foramen area were evaluated retrospectively on panoramic radiographs. Patients were divided into two groups regarding implant proximity to the IAC (Group 1, distance ?2 mm, Group 2, distance >2 mm). Postoperative neurosensory complications (pain and paresthesia) were recorded. Chi-square test was used for statistical comparison and P ? 0.05 was considered significant. Results: One hundred and fifty-three implants (32.2%) were inserted closer than 2 mm to the IAC whereas 321 implants (67.8%) were inserted further than 2 mm. Three implants which had a distance of 0 mm to the IAC (0.63%) caused paresthesia after surgery. Implant distance to IAC did not show a significant difference regarding pain and paresthesia (P = 0.06 and P = 0.08, respectively). Conclusion: When 2 mm is considered as a safety distance, the distance of the implants to the IAC did not yield any statistical difference regarding postoperative neurosensory complications.en_US
dc.language.isoengen_US
dc.publisherMedknow Publicationsen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 Unported*
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/*
dc.subjectDental Implantsen_US
dc.subjectInferior Alveolar Nerve Injuryen_US
dc.subjectNeurosensory Complicationen_US
dc.titleIs 2 mm a safe distance from the inferior alveolar canal to avoid neurosensory complications in implant surgery?en_US
dc.typearticleen_US
dc.relation.ispartofNigerian Journal of Clinical Practiceen_US
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalıen_US
dc.authorid0000-0001-5984-0096en_US
dc.authorid0000-0003-3347-1151en_US
dc.authorid0000-0002-6705-3110en_US
dc.identifier.volume20en_US
dc.identifier.issue3en_US
dc.identifier.startpage274en_US
dc.identifier.endpage277en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.4103/1119-3077.183240en_US
dc.identifier.wosqualityQ4en_US
dc.identifier.scopusqualityQ3en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster

info:eu-repo/semantics/openAccess
Aksi belirtilmediği sürece bu öğenin lisansı: info:eu-repo/semantics/openAccess