Basit öğe kaydını göster

dc.contributor.advisorŞakul, Bayram Ufuk
dc.contributor.authorSöyler, Osman
dc.date.accessioned2021-08-19T12:37:21Z
dc.date.available2021-08-19T12:37:21Z
dc.date.issued2020en_US
dc.date.submitted2020-03-11
dc.identifier.citationSöyler, O. (2020). Geriatrik bireylerde farklı yoğunlukta tabanlıkların ayak yük dağılımı ve statik denge üzerine etkilerinin incelenmesi. (Yayınlanmamış yüksek lisans tezi). İstanbul Medipol Üniversitesi Sağlık Bilimleri Enstitüsü, İstanbul.en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12511/7885
dc.description.abstractBu çalışma, geriatrik bireylerde farklı yoğunlukta tabanlıkların ayak yük dağılımı ve statik denge üzerine etkilerini araştırmak için tasarlandı. Çalışmaya 65 yaş üstü 30 sağlıklı birey dahil edildi. Bireylere EVA (Etil Vinil Asetat) ile yapılmış sertlikleri 25 shore, 35 shore, ve 45 shore olan tabanlıklar verildi. Tabanlıklar, Diasu Yürüme Analizi Cihazı (Diasu, Sani Corparate via Giacomo Peroni 400 00131, Rome IT) ile taraması yapılarak bireylere en uygun şekilde Milletrix Yürüme Analiz yazılım programı ile bilgisayar ortamında işlendikten sonra CNC (Computerized Numerical Control) cihazından üretildi. Değerlendirme parametrelerinde Milletrix Yürüme Analiz Yazılımı kullanıldı. Bireyler kişiye özel olarak hazırlanan tabanlıklar ile stabilometrik değerlendirmede gözler açık ve kapalı olarak değerlendirildi. Aynı cihazda statik değerlendirmede ise bireyler, gözler açık ve kapalı duruş pozisyonunda değerlendirildi. İstatistiksel analiz IBM SPSS Statistics 21.0 (SPSS Inc, Chicago, IL, ABD) ile yapıldı. Kolmogorov-Smirnov Testi ile verilerin normal dağılım göstermediği görüldü. Kişilerin kullanımına bağlı değişimini ve farkın hangi uygulamadan kaynaklandığını belirlemek için yapılan tekrarlı ölçümlerde ANOVA, Friedman ve Wilcoxon testi kullanıldı. Nitel veriler sayı ve yüzde (n, %) ile, nicel veriler median, min ve max değerleri, %25 ve %75 percentil ile ifade edildi. Sağ-sol taraf farkı ile gözler açık ve kapalı ölçümlerin karşılaştırılmasında Wilcoxon testi kullanıldı. p değeri 0,05 olarak alındı. Tabanlıksız ve farklı yoğunlukta tabanlıkların ayak yük dağılımı ve statik denge sonuçları açısından farklı olmadığı (p>0.05), sağ ve sol taraf ölçüm sonuçlarında sağ taraf lehine (p<0.05), gözler açık ve kapalı ölçümlerde gözler açık lehine (p<0.05) yük dağılımı ve statik dengenin etkilendiği belirlenmiştir. Sonuç olarak, normal yük dağılımı, statik dengenin sağlanması ve sürdürülmesinde, farklı yoğunluktaki tabanlıktan ziyade gözler açık pozisyonun görsel girdi sağlaması nedeniyle daha etkili olduğu gösterildi.en_US
dc.description.abstractThis thesis was designed to investigate the effects of different density insoles on foot load distribution and static balance in geriatric individuals. 30 healthy individuals over 65 years old were included in the study. Individuals were given insoles made of EVA (Ethyl Vinyl Acetate) with 25 shore, 35 shore, and 45 shore bases. Insoles were produced from CNC (Computerized Numerical Control) device after being scanned with Diasu Walking Analysis Device (Diasu, Sani Corparate via Giacomo Peroni 400 00131, Rome IT) and processed in computer environment with Milletrix Gait Analysis software program in the most appropriate way. Milletrix Gait Analysis Software was used in the evaluation parameters. The eyes were evaluated open and closed in the stabilometric evaluation with the insoles prepared specifically for the individual. In the static evaluation of the same device, individuals were evaluated with their eyes open and closed. Statistical analysis was performed with IBM SPSS Statistics 21.0 (SPSS Inc, Chicago, IL, USA). With the Kolmogorov-Smirnov Test, the data were not normally distributed. ANOVA, Friedman and Wilcoxon test was used in repeated measurements to determine the change in the use of the individuals and from which application the difference originated. Qualitative data were expressed as numbers and percentages (n,%), quantitative data were expressed as median, min and max values, 25% and 75% percentil. Wilcoxon test was used to compare right-left side difference with open and closed eyes. p value was taken as 0.05. Insoles without foot and different density are not different in terms of foot load distribution and static balance results (p> 0.05), right and left side measurement results in favor of right side (p <0.05), eyes open and closed measurements in favor of eyes open (p <0.05) distribution and static balance were determined to be affected. As a result, it has been shown to be more effective in maintaining and maintaining the normal load distribution, static equilibrium, as the eyes open position provides visual input rather than insoles with different density.en_US
dc.language.isoturen_US
dc.publisherİstanbul Medipol Üniversitesi Sağlık Bilimleri Enstitüsüen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAyak Yük Dağılımıen_US
dc.subjectGeriatriken_US
dc.subjectStatik Dengeen_US
dc.subjectTabanlıken_US
dc.subjectSertliken_US
dc.subjectFoot Load Distributionen_US
dc.subjectGeriatricen_US
dc.subjectInsolesen_US
dc.subjectStatic Balanceen_US
dc.subjectShoreen_US
dc.titleGeriatrik bireylerde farklı yoğunlukta tabanlıkların ayak yük dağılımı ve statik denge üzerine etkilerinin incelenmesien_US
dc.title.alternativeInvestigate the effects of different density insoles on foot load distribution and static balance in geriatric individualsen_US
dc.typemasterThesisen_US
dc.departmentİstanbul Medipol Üniversitesi, Sağlık Bilimleri Enstitüsü, Ortez ve Protez Ana Bilim Dalıen_US
dc.relation.publicationcategoryTezen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster