Basit öğe kaydını göster

dc.contributor.authorUslu, Gülşah
dc.contributor.authorÖzyürek, Taha
dc.contributor.authorGündoğar, Mustafa
dc.contributor.authorYılmaz, Koray
dc.date.accessioned2021-01-26T12:09:05Z
dc.date.available2021-01-26T12:09:05Z
dc.date.issued2018en_US
dc.identifier.citationUslu, G., Özyürek, T., Gündoğar, M. ve Yılmaz, K. (2018). Cyclic fatigue resistance of 2Shape, twisted file and EndoSequence xpress nickel-titanium rotary files at intracanal temperature. Journal of Dental Research Dental Clinics Dental Prospects, 12(4), 283-287. https://dx.doi.org/10.15171/joddd.2018.044en_US
dc.identifier.issn2008-210X
dc.identifier.issn2008-2118
dc.identifier.urihttps://dx.doi.org/10.15171/joddd.2018.044
dc.identifier.urihttps://hdl.handle.net/20.500.12511/6403
dc.description.abstractBackground. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape TS1 (25/.04), 20 TF (25/.04) and 20 ESX (25/.04) files were tested for cyclic fatigue at intracanal temperature (35°C). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds using a digital chronometer and the number of cycles to fracture (NCF) for each file was calculated. Kruskal-Wallis test with Bonferroni correction was performed to statistically analyze data using SPSS 21.0. Statistical significance was set at P<0.05. Results. NCF values revealed that the 2Shape had significantly the highest cyclic fatigue resistance, followed by TF and ESX at intracanal temperature (P<0.05). The difference was significant between the TF and ESX groups (P<0.05). There was no significant difference among the 2Shape, TF and ESX files with respect to the lengths of the fractured file fragments (P>0.05). Conclusion. Within the limitations of present study, it was concluded that the cyclic fatigue resistance of 2Shape files at the intracanal temperature is higher than that of TF and ESX files.en_US
dc.language.isoengen_US
dc.publisherTabriz University of Medical Sciences, Faculty of Dentistryen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution 4.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectCyclic Fatigueen_US
dc.subjectEndoSequence Xpressen_US
dc.subjectTwisted Fileen_US
dc.subject2Shapeen_US
dc.subjectStatic Testen_US
dc.titleCyclic fatigue resistance of 2Shape, twisted file and EndoSequence xpress nickel-titanium rotary files at intracanal temperatureen_US
dc.typearticleen_US
dc.relation.ispartofJournal of Dental Research Dental Clinics Dental Prospectsen_US
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Endodonti Ana Bilim Dalıen_US
dc.authorid0000-0001-8656-7101en_US
dc.identifier.volume12en_US
dc.identifier.issue4en_US
dc.identifier.startpage283en_US
dc.identifier.endpage287en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.15171/joddd.2018.044en_US