Basit öğe kaydını göster

dc.contributor.authorEliaçık, Mustafa
dc.contributor.authorKırgız, Ahmet
dc.contributor.authorAygün, Beril
dc.date.accessioned2020-11-16T06:00:47Z
dc.date.available2020-11-16T06:00:47Z
dc.date.issued2020en_US
dc.identifier.citationEliaçık, M., Kırgız, A. ve Aygün, B. (2020). Evaluation of corneal thickness with spectral-domain optical coherence tomography following keraring implantation for keratoconus: Five year follow-up. Current Eye Research, 45(11), 1359-1363. https://dx.doi.org/10.1080/02713683.2020.1749667en_US
dc.identifier.issn0271-3683
dc.identifier.issn1460-2202
dc.identifier.urihttps://dx.doi.org/10.1080/02713683.2020.1749667
dc.identifier.urihttps://hdl.handle.net/20.500.12511/6029
dc.description.abstractTo evaluate the change in the position of intrastromal corneal ring segments (ICRS) implanted in keratoconus patients within five years of implantation. Participants in this study included keratoconus patients who received Keraring 10 ICRS implantation and had a follow-up time of at least 5 years. The distances from apex to anterior corneal surface (AA), from outer basal corner to posterior corneal surface (BP), and from inner basal corner to posterior corneal surface (CP) were measured at every postoperative visit (6 months, 1 year, 3 years, and 5 years) and compared to each other. Thirty eyes of 22 patients were included. The CP showed a statistically significant decrease at all 15 time points (p < .001); however, no statistically significant difference was found at 5 years regarding AA or BP (p > .05 for all). Triangular ICRS implanted in keratoconus patients remained stable for five years without any complications, which is an extremely important aspect of ICRS surgery. The only difference was a slight posterior movement of the inner basal corner, although without anterior chamber perforation.en_US
dc.language.isoengen_US
dc.publisherTaylor and Francis Ltd.en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectKeratoconusen_US
dc.subjectKeraring Implantationen_US
dc.subjectCorneal Thicknessen_US
dc.subjectCoherence Tomographyen_US
dc.titleEvaluation of corneal thickness with spectral-domain optical coherence tomography following keraring implantation for keratoconus: Five year follow-upen_US
dc.typearticleen_US
dc.relation.ispartofCurrent Eye Researchen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalıen_US
dc.authorid0000-0002-2563-2149en_US
dc.identifier.volume45en_US
dc.identifier.issue11en_US
dc.identifier.startpage1359en_US
dc.identifier.endpage1363en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1080/02713683.2020.1749667en_US
dc.identifier.wosqualityQ3en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster