dc.contributor.authorErdur Karaman, Sevil
dc.contributor.authorÇelik, Uğur
dc.contributor.authorEren, Hakan
dc.contributor.authorAygıt, Ebru Demet
dc.contributor.authorGüngel, Hülya
dc.date.accessioned08.07.201910:49:13
dc.date.accessioned2019-07-08T20:19:02Z
dc.date.available08.07.201910:49:13
dc.date.available2019-07-08T20:19:02Z
dc.date.issued2015en_US
dc.identifier.citationErdur Karaman, S., Çelik, U., Eren, H., Aygıt, E. D. ve Güngel, H. (2015). Fakoemülsifikasyon cerrahisi sonrası kornea biyomekanik özelliklerinin değişimi. Glokom Katarakt, 10(4), 263-266.en_US
dc.identifier.issn1305-9173
dc.identifier.urihttps://hdl.handle.net/20.500.12511/583
dc.description.abstractAmaç: Fakoemülsifikasyon sonrası göz içi merceği yerleştirilmesinden sonra Ocular Response Analyzer (ORA) cihazı ile göz içi basıncı (GİB) ve korneal biyomekanik özelliklerdeki değişimleri incelemek.Gereç ve Yöntem: Çalışmaya katarakt cerrahisi yapılan 63 hastanın 63 gözü dosya üzerinden geriye dönük taranarak dahil edildi. Korneal histerezis (KH), korneal direnç faktörü (KDF), korneal kompanze GİB (GİBkk) ve Goldmann GİB (GİBg) ölçümleri ameliyat öncesi ve sonrası 1. Hafta, 1. Ay, 3. Ayda ORA cihazı ile ölçüldü. Merkezi kornea kalınlığı (MKK) ölçümü ise Orbscan II cihazı ile yapıldı.Bulgular: Ortalama KH preoperatif 10.28±1.61 mmHg iken 9.57±1.70 mmHg'ya anlamlı bir düşüş gösterdi (p=0.001), fakat postoperatif 3. Ayda 10.21±1.61 mmHg idi (p=0.9). Ortalama KDF preoperatif 10.61±1.89 mmHg iken 9.61±1.92 mmHg'ya anlamlı bir düşüş gösterdi (p=0.001), fakat postoperatif 3. Ayda 10.21±1.61 mmHg idi (p=0.8). Ortalama GİBg postoperatif dönemde preoperatif öçümlerine göre anlamlı olarak düşük bulundu (1. hafta p=0.03, 1. ay p= 0.01, 3. ay p=0.009). Ortalama GİBkk preoperatif ve postoperatif 1. hafta ve 1. ayda değerleri arasında istatiksel anlamlı bir değişiklik saptanmadı (p=0.8, p= 0.2), fakat 3. ayda anlamlı olarak düşük izlendi (p=0.04). Tartışma: Fakoemülsifikasyon cerrahisi sonrası ortalama KH, KDF erken dönemde farklılık göstermesine rağmen 3 aylık takip döneminde anlamlı fark sergilemedi. Ortalama GİBkk ve GİBg değerlerinde ameliyat sonrası düşüş görülmektedir. Bu durum korneal saydam kesili fakoemülsifikasyon sonrası erken dönemde kornea biyomekaniğinin etkilendiğini göstermektediren_US
dc.description.abstractPurpose: To evaluate corneal viscoelastic and intraocular pressure (IOP) changes measured by an ocular response analyzer (ORA) after phacoemulsification and intraocular lens (IOL) implantation. Materials and Methods: Sixty-three eyes scheduled for cataract surgery were included in the study. Corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc) and Goldmann-correlated IOP (IOPg) were measured by ORA preoperatively and postoperative 1st week, 1st month and 3rd month. Central corneal thickness (CCT) was measured using Orbscan II.Results: The mean CH decreased significantly from 10.28±1.61 mmHg preoperatively to 9.57±1.70 mmHg at 1 week (p=0.004) however increased to 10.21±1.61 mmHg at 3 month (p=0.9). The mean CRF decreased significantly from 10.61±1.89 mmHg preoperatively to 9.61±1.92 mmHg at 1 week (p=0.004) however increased to 10.51±1.69 mmHg at 3 month (p=0.8). The mean preoperative IOPg was decreased significantly in all postoperative measurements, (1st week p=0.03, 1st month p=0.01, 3rd month p=0.009). The mean preoperative IOPcc did not change significantly by first week and 1st month postoperatively (p=0.8, p= 0.2), however decreased significantly at 3rd month control.(p=0.04)Conclusions: Even the CH, CRF values decreased significantly in early postoparative period after phacoemulsification surgery, there was no change according to preoperative values in 3 months follow up. Mean İOPg and IOPcc values decreased in the postoperative period. That was showing that corneal biomechanical properties are influenced by phacoemulsification and IOL implantationen_US
dc.language.isoturen_US
dc.publisherGazi Göz Vakfı Yayınlarıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectKornea Biyomekaniğien_US
dc.subjectStandart Saydam Korneal Kesili Fakoemülsifikasyon Cerrahisien_US
dc.subjectOküler Cevap Analizörüen_US
dc.subjectORAen_US
dc.subjectKorneal Histerezisen_US
dc.subjectCorneal Biomechanical Propertiesen_US
dc.subjectStandard Clear Corneal Phacoemulsification Surgeryen_US
dc.subjectOcular Response Analyzeren_US
dc.subjectCorneal Hysteresisen_US
dc.titleFakoemülsifikasyon cerrahisi sonrası kornea biyomekanik özelliklerinin değişimien_US
dc.title.alternativeChanges in corneal biomechanical properties after phacoemulsification surgeryen_US
dc.typearticleen_US
dc.relation.ispartofGlokom Katarakten_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalıen_US
dc.authorid0000-0001-9829-7268en_US
dc.identifier.volume10en_US
dc.identifier.issue4en_US
dc.identifier.startpage263en_US
dc.identifier.endpage266en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US