Basit öğe kaydını göster

dc.contributor.authorKaraca, Oğuz
dc.contributor.authorGüneş, Hacı Murat
dc.contributor.authorÇakal, Beytullah
dc.contributor.authorBarutçu, İrfan
dc.contributor.authorTürkmen, Muhsin
dc.date.accessioned2020-07-10T14:13:01Z
dc.date.available2020-07-10T14:13:01Z
dc.date.issued2015en_US
dc.identifier.citationKaraca, O., Güneş, H. M., Çakal, B., Barutçu, İ. ve Türkmen, M. (2015). Use of a double-covered stent-in-stent technique to manage persistent coronary perforation. Kosuyolu Heart Journal, 18(3), 155-155. https://dx.doi.org/10.5578/khj.9946en_US
dc.identifier.issn2149-2972
dc.identifier.urihttps://dx.doi.org/10.5578/khj.9946
dc.identifier.urihttps://hdl.handle.net/20.500.12511/5456
dc.description.abstractA sixty-four year old man with a previous history of CABG was referred for coronary angiography that revealed a critical stenosis of the right posterior descending artery at the anastomosis point of the saphenous vein graft (Figure A). Percutaneous intervention was initiated by engagement of the saphenous graft ostium with a 6F JR guiding catheter, followed by crossing the lesion with a hydrophilic guidewire. A drug-eluting stent, 2.25 x 23 mm in size, (Xience, Abbott Vascular, USA) was implanted at 14 atm pressure. Control angiography revealed a marked Ellis type IV coronary perforation with leakage of blood into the pericardial cavity (Figure B). Subsequently, the patient deteriorated hemodynamically with severe chest pain and hypotension. Echocardiography showed a marked pericardial effusion along with right ventricular collapse. Protamine sulfate was used to reverse anticoagulation followed by administration of IV fl uids and emergency pericardiocentesis. A 2.5 x 15 mm balloon (Sprinter Legend, Medtronic, USA) was advanced for 10 minutes of prolonged infl ation, which failed to heal the perforation (Figure C). A 2.80 x 19 mm covered stent (Graftmaster, Abbott Vascular, USA) was implanted at the level of the perforation.en_US
dc.language.isoengen_US
dc.publisherBilimsel Tıp Yayınevien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDouble-Covered Stenten_US
dc.subjectTechnique to Manage Persistenten_US
dc.subjectCoronary Perforationen_US
dc.titleUse of a double-covered stent-in-stent technique to manage persistent coronary perforationen_US
dc.title.alternativeİnatçı koroner perforasyon olgusunda iç içe kaplı stent kullanımıen_US
dc.typeotheren_US
dc.relation.ispartofKosuyolu Heart Journalen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Kardiyoloji Ana Bilim Dalıen_US
dc.authorid0000-0002-4281-0867en_US
dc.authorid0000-0001-5825-8627en_US
dc.authorid0000-0003-0230-6575en_US
dc.identifier.volume18en_US
dc.identifier.issue3en_US
dc.identifier.startpage155en_US
dc.identifier.endpage155en_US
dc.relation.publicationcategoryDiğeren_US