Ara
Toplam kayıt 11, listelenen: 1-10
Near zero fluoroscopy radiation exposure during successful catheter ablation of atrial tachycardia from the non-coronary aortic cusp using 3-dimentional electroanatomic mapping system
(AVES, 2014)
Atrial tachycardia (AT) rarely originates from the paraHisian region (1). Catheter ablation of paraHisian AT carries a substantial risk of atrioventricular (AV) block. Cryoablation offers a safer ablation strategy for these ...
Impact of aortic stiffness on the frequency of paroxysmal atrial fibrillation recurrences
(Taylor & Francis, 2015)
Background The relationship between arterial stiff ness (AS) and atrial fi brillation (AF) incidence is well-known. In this study we aimed to investigate the relationship between AS parameters and AF occurence as well as ...
Effect of pulmonary vein anatomy and pulmonary vein diameters on outcome of cryoballoon catheter ablation for atrial fibrillation
(Wiley, 2015)
BackgroundIn this study, we aimed to determine pulmonary vein (PV) variation patterns in patients undergoing cryoballoon ablation for atrial fibrillation (AF) and their impacts on procedural success and recurrence and also ...
Pocket haematoma after cardiac electronic device implantation in patients receiving antiplatelet and anticoagulant treatment: A single-centre experience
(Taylor and Francis, 2017)
Objective In modern cardiology practice, implantation of cardiac electronic devices in patients taking anticoagulant or antiplatelet therapy is a common clinical scenario. Bleeding complications are of particular concern ...
Changes in electrocardiographic p wave parameters after cryoballoon ablation and their association with atrial fibrillation recurrence
(Wiley-Blackwell, 2016)
Background: Changes in P wave parameters after circumferential pulmonary vein isolation (CPVI) have been previously identified. In this study, we aimed to determine the changes in P wave parameters surface electrocardiogram ...
Asymptomatic pulmonary embolism after ablation
(Karger, 2016)
Background: Pulmonary embolism (PE) is a life-threatening event with a broad presentation spectrum ranging from asymptomatic cases to sudden cardiac arrest. It is unclear if right atrial emboli cause PE in patients with ...
Myocardial injury biomarkers after radiofrequency catheter and cryoballoon ablation for atrial fibrillation and their impact on recurrence
(Via Medica, 2017)
Background: Myocardial injury induced by catheter ablation (CA) for atrial fibrillation (AF) leads to elevated biomarker levels. Aim: This prospective study examined levels of myocardial injury biomarkers (creatinine kinase ...
The relationship between the S-wave in lead 1 and recurrence of RVOT PVC ablation
(Churchill Livingstone Inc Medical Publishers, 2018)
Background: Radiofrequency catheter ablation (CA) is a common non-pharmacological treatment option for ventricular premature contractions (PVCs) originating from right ventricular outflow tract (RVOT). In this study, we ...
Relationship between serum osteopontin level and atrial fibrillation recurrence in patients undergoing cryoballoon catheter ablation
(Turkish Society of Cardiology, 2017)
Objective: Atrial fibrillation (AF) is the most common sustained arrhythmia and is associated with increased morbidity and mortality. Atrial fibrosis augments recurrence rate following AF catheter ablation. Osteopontin is ...
Evaluation of adult versus pediatric transesophageal echocardiography probe efficiency for guiding septal puncture during atrial fibrillation ablation
(Blackwell Publishing, 2015)
PurposeTransesophageal echocardiography (TEE) has a pivotal role in invasive cardiology practice in terms of guiding a variety of procedures. It is challenging to perform TEE examination with sedated patients due to ...