Ara
Toplam kayıt 48, listelenen: 41-48
Compared efficacy of intra-articular injection of methylprednisolone and triamcinolone
(Sociedade Brasileira de Ortopedia e Traumatologia, 2017)
Objective: To compare the effect of two different corticosteroid types in bilateral and symmetrical knee osteoarthritis (OA). Methods: One hundred and twenty-six patients received injections of methylprednisolone acetate ...
Ultrasonography or direct radiography? A comparison of two techniques to detect dorsal screw penetration after volar plate fixation
(Biomed Central Ltd., 2018)
Background: Complications related to extensor tendons have begun to increase with the use of volar plates in the treatment of distal radius fractures. In this study, we aimed to compare four-plane radiography and ultrasonography ...
Comparison of mortality rates and functional results after transtibial and transfemoral amputations due to diabetes in elderly patients-a retrospective study
(Elsevier Science Bv, 2016)
Introduction: This study aimed to compare mortality rates and functional results of transtibial and transfemoral amputations in elderly patients with diabetes. Methods: 87 amputees [54 (62.1%) transtibial and 33 (37.9%) ...
A new method for diagnosis of anterior cruciate ligament tear: MRI with maximum flexion of knee in the prone position: A case control study
(Elsevier, 2019)
Background: The diagnosis of anterior cruciate ligament tear can be made by physical examination and magnetic resonance imaging (MRI) in the supine position. In cases where the tear is partially evaluated on MRI, the choice ...
Flexor tendon complications in comminuted distal radius fractures treated with anatomic volar rim locking plates
(Turkish Association of Orthopaedics and Traumatology, 2016)
Objective: Anatomic volar rim locking plates are designed with the aim of treating intraarticular distal radius fractures. When used to treat comminuted distal radius fractures, these plates can damage the flexor tendons. ...
Can double fluoroscopy in the oblique position reduce surgical time and radiation exposure during intertrochanteric femur fracture nailing?
(Turkish Assoc Trauma Emergency Surgery, 2018)
BACKGROUND: The purpose of this study was to determine the comparative effectiveness of the use of single fluoroscopy versus double fluoroscopy during intramedullary nailing in the oblique position for intertrochanteric ...
Treatment of open fractures with a computer-assisted external fixator system without the use of fluoroscopy
(BMC, 2016)
Background: Developed for the treatment of deformity correction, computer-assisted circular external fixators in recent years have also been used for fracture fixation. In this study, we aimed to present the efficacy of ...
Comparison of medial arch-supporting insoles and heel pads in the treatment of plantar fasciitis
(University of Kragujevac, Faculty of Science, 2015)
Plantar fasciitis is a disorder caused by inflammation of the insertion point of the plantar fascia over the medial tubercle of the calcaneus. Foot orthotics are used to treat plantar fasciitis. Heel pads medialise the ...