Basit öğe kaydını göster

dc.contributor.authorCanpolat, Gamze
dc.contributor.authorÖzgültekin, Asu
dc.contributor.authorBoran, Ömer Faruk
dc.date.accessioned2019-12-27T17:03:01Z
dc.date.available2019-12-27T17:03:01Z
dc.date.issued2019en_US
dc.identifier.citationCanpolat, G., Özgültekin, A. ve Boran, Ö. F. (2019). Comparison of bilevel positive airway pressure and average volume-assured pressure support mode in terms of patient compliance and treatment success in hypercapnic patients. A cross-sectional study. Annali Italiani di Chirurgia, 90(5), 392-397.en_US
dc.identifier.issn0003-469X
dc.identifier.issn2239-253X
dc.identifier.urihttps://hdl.handle.net/20.500.12511/4785
dc.description.abstractAIM: It is necessary for an effective NIV application to provide proper modality selection, sufficient minute ventilation (MV), also the amount of leakage on the circuit must be minimized and patient-ventilator adaptation must be achieved. METHODS: 30 patients with acute respiratory failure as a result of either internal or postoperative reasons were included in the study. Patient comfort was analyzed with a scale ranging from 0 to 2. Firstly the patient was used for two hours in BIPAP modality, after then the AVAPS modality (Period Av) was applied by setting the required rates the same mask. During BIPAP and AVAPS, arterial blood gases analysis, comfort scale and hemodynamic parameters were recorded in the 30th minute, 1st hour and 2nd hour. RESULTS: According to the assessment of arterial blood gases, the pH changes of both periods were statistically significant compared to their baseline values (p=0.001). Treatment compliance of the patients was significantly better at AVAPS modality at all times (p = 0.015, p = 0.008, p = 0.008, respectively). CONCLUSIONS: According to the results obtained from this study, the AVAPS modality has positive effects on pH and gas variation and patient comfort; therefore, it can be confidently used in clinical practice.en_US
dc.language.isoengen_US
dc.publisherEdizioni Luigi Pozzien_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectAverage Volume Assured Pressure Supporten_US
dc.subjectBilevel Continuous Positive Airway Pressureen_US
dc.subjectIntensive Care Unitsen_US
dc.subjectNoninvasive Ventilationen_US
dc.subjectPatients Complianceen_US
dc.titleComparison of bilevel positive airway pressure and average volume-assured pressure support mode in terms of patient compliance and treatment success in hypercapnic patients. A cross-sectional studyen_US
dc.typearticleen_US
dc.relation.ispartofAnnali Italiani di Chirurgiaen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Anesteziyoloji ve Reanimasyon Ana Bilim Dalıen_US
dc.authorid0000-0002-7322-5070en_US
dc.identifier.volume90en_US
dc.identifier.issue5en_US
dc.identifier.startpage392en_US
dc.identifier.endpage397en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.wosqualityQ4en_US
dc.identifier.scopusqualityQ3en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster