Basit öğe kaydını göster

dc.contributor.authorGök, Gülay
dc.contributor.authorSayar, Nurten
dc.contributor.authorÖz, Dilaver
dc.contributor.authorErer, Hatice Betül
dc.contributor.authorEkmekçi, Ahmet
dc.contributor.authorEren, Mehmet
dc.date.accessioned2019-12-27T09:40:37Z
dc.date.available2019-12-27T09:40:37Z
dc.date.issued2020en_US
dc.identifier.citationGök, G., Sayar, N., Öz, D., Erer, H. B., Ekmekçi, A. ve Eren, M. (2020). Comparison of 2D vena contracta area with 3D planimetric mitral valve area in rheumatoid mitral valve disease. International Journal of Cardiovascular Imaging, 36(11), 2115-2120. http://doi.org/10.1007/s10554-019-01673-yen_US
dc.identifier.issn1569-5794
dc.identifier.issn1573-0743
dc.identifier.urihttp://doi.org/10.1007/s10554-019-01673-y
dc.identifier.urihttps://hdl.handle.net/20.500.12511/4768
dc.description.abstractRheumatoid valve disease is a general health problem of developing countries, and it mainly affects after the age of 40. Assessment of the correct mitral valve area (MVA) is important for the treatment of rheumatoid valve disease. However, there are contradictions between the three-dimensional (3D) and two-dimensional (2D) methods. A measurement with 3D echocardiography is a more accurate method to measure the MVA. However, in centers without 3D echocardiography, there are some difficulties in the accurate measurement of the MVA. The aim of this study was to assess the value of 2D transesophageal echocardiography (TEE) mitral valve vena contracta area (VCA) in predicting the severity of rheumatoid mitral stenosis (RMS) by comparing 3D planimetry. A total of 24 patients (10 females and 14 males) who were diagnosed with mild/moderate/severe RMS with using pressure half time, mean transmitral gradient, and planimetry methods were included in this study. 3D images were acquired using the 3D zoom and full volume. 2D TEE VCA was measured at an angle of 140° and 60°, which was perpendicular to the former, with color Doppler and the VCA was measured with an ellipsoid area using mathematical formula. There was statistically significant relationship between the measurements of 2D VCA and 3D zoom mode MVA planimetry and MVA full measurements (MVA full volume) (p < 0.01). Calculation of the valvular area after measuring the mitral valve VCA with 2D TEE is a reliable method that is usable in centers without 3D echocardiography.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subject3D-Echocardiographyen_US
dc.subjectMitral Stenosisen_US
dc.subjectTransesophageal Echocardiogrpahyen_US
dc.titleComparison of 2D vena contracta area with 3D planimetric mitral valve area in rheumatoid mitral valve diseaseen_US
dc.typearticleen_US
dc.relation.ispartofInternational Journal of Cardiovascular Imagingen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Kardiyoloji Ana Bilim Dalıen_US
dc.authorid0000-0003-0205-1138en_US
dc.identifier.volume36en_US
dc.identifier.issue11en_US
dc.identifier.startpage2115en_US
dc.identifier.endpage2120en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1007/s10554-019-01673-yen_US
dc.identifier.wosqualityQ3en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster