Ara
Toplam kayıt 7, listelenen: 1-7
Servikal omurga sonlu eleman modellemesinde, model geometrisinin biyomekanik parametrelere olan etkisi
(Institute of Electrical and Electronics Engineers, 2015)
İnterspinus implantları, omurga stenosis ve faset artiritis gibi omurga patolojileri için kullanıldığı bilinir. Tasarımındaki ana düşünce spinos proseslere kuvvet uygulayarak birbirinden uzaklaştırmak ve klinisyenlerin ...
Biomechanical study on three screw-based atlantoaxial fixation techniques: A finite element study
(Korean Society of Spine Surgery, 2022)
Study Design: This is a finite element study. Purpose: This study is aimed to compare the biomechanical behaviors of three screw-based atlantoaxial fixation techniques. Overview of Literature: Screw-based constructs that ...
Lumbar single-level dynamic stabilization with semi-rigid and full dynamic systems: A retrospective clinical and radiological analysis of 71 patients
(Korean Orthopaedic Association, 2017)
Background: This study compares the clinical and radiological results of three most commonly used dynamic stabilization systems in the field of orthopedic surgery. Methods: A total of 71 patients underwent single-level ...
Influence of three-dimensional reconstruction method for building a model of the cervical spine on its biomechanical responses: A finite element analysis study
(Hindawi Publishing Corporation, 2016)
In some finite element analysis studies of models of sections of the spine, the three-dimensional solid model is built by assuming symmetry about the mid-sagittal plane of the section, whereas in other studies, the model ...
Motion analysis study on sensitivity of finite element model of the cervical spine to geometry
(SAGE Publishing Ltd, 2016)
Numerous finite element models of the cervical spine have been proposed, with exact geometry or with symmetric approximation in the geometry. However, few researches have investigated the sensitivity of predicted motion ...
Complications of 2-level dynamic stabilization: A correlative clinical and radiological analysis at two-year follow-up on 103 patients
(Turkish Neurosurgical Society, 2018)
AIM: To investigate the postoperative complications, such as screw loosening, screw breakage and adjacent segment disease (ASD), in patients who underwent surgery with 2-level dynamic stabilization systems. MATERIAL and ...
How to reduce stress on the pedicle screws in thoracic spine? Importance of screw trajectory: A finite element analysis
(Turkish Neurosurgical Society, 2019)
AIM: To investigate the biomechanical comparison of thoracic transpedicular screw trajectories on the sagittal plane. MATERIAL and METHODS: A three-dimensional, non-linear finite element analysis (FEA) model of T8 through ...