dc.contributor.author | Çıplak, Necati Mert | |
dc.contributor.author | Süzer, Tuncer | |
dc.contributor.author | Şentürk, Salim | |
dc.contributor.author | Yaman, Onur | |
dc.contributor.author | Sasani, Mehdi | |
dc.contributor.author | Öktenoğlu, Tunç | |
dc.contributor.author | Yılmaz, Atilla | |
dc.contributor.author | Erbulut, Deniz Ufuk | |
dc.contributor.author | Özer, Ali Fahir | |
dc.date.accessioned | 10.07.201910:49:13 | |
dc.date.accessioned | 2019-07-10T20:04:11Z | |
dc.date.available | 10.07.201910:49:13 | |
dc.date.available | 2019-07-10T20:04:11Z | |
dc.date.issued | 2018 | en_US |
dc.identifier.citation | Çıplak, N. M., Süzer, T., Şentürk, S., Yaman, O., Sasani, M., Öktenoğlu, T. ... Özer, A. F. (2018). Complications of 2-level dynamic stabilization: A correlative clinical and radiological analysis at two-year follow-up on 103 patients. Turkish Neurosurgery, 28(5), 756-762. https://dx.doi.org/10.5137/1019-5149.JTN.21036-17.1 | en_US |
dc.identifier.issn | 1019-5149 | |
dc.identifier.uri | https://dx.doi.org/10.5137/1019-5149.JTN.21036-17.1 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12511/4010 | |
dc.description | WOS: 000443444000010 | en_US |
dc.description | PubMed ID: 30192368 | en_US |
dc.description.abstract | AIM: To investigate the postoperative complications, such as screw loosening, screw breakage and adjacent segment disease (ASD), in patients who underwent surgery with 2-level dynamic stabilization systems. MATERIAL and METHODS: Postoperative complications, clinical improvements and radiological parameters in patients who underwent surgery using a dynamic system for 2-level lumbar stabilization were retrospectively reviewed. A total of 103 patients with lumbar degenerative spinal instability underwent 2-level dynamic stabilization. Clinical findings were reviewed at 2-year follow-up. Screw breakage and loosening were evaluated during this duration together with clinical findings. RESULTS: Visual analog scale (VAS) and Oswestry Disability Index (ODI) scores were significantly decreased at the four-month evaluation, and they were also decreased at the 1-year follow up and at the 24th postoperative month. ASD was diagnosed in twelve (8 females, 4 males) of the 103 patients in the follow-up radiological and clinical controls. There were 9 screw breakages and 4 screw loosening cases. The complication rate of 2-level dynamic stabilization was high in this study. CONCLUSION: Our results showed that complications (screw loosening or breakage and adjacent segment disease) are not rare after 2-level dynamic stabilization, unlike the acceptable results with the single-level dynamic system. The most probable explanation is that the instrument system behaves more rigidly with every additional segment. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Turkish Neurosurgical Society | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Dynamic Rod | en_US |
dc.subject | Dynamic Stabilization | en_US |
dc.subject | Dynamic System | en_US |
dc.subject | Hinged Screw | en_US |
dc.subject | Lumbar Degenerative Disease | en_US |
dc.title | Complications of 2-level dynamic stabilization: A correlative clinical and radiological analysis at two-year follow-up on 103 patients | en_US |
dc.type | article | en_US |
dc.relation.ispartof | Turkish Neurosurgery | en_US |
dc.department | İstanbul Medipol Üniversitesi, Mühendislik ve Doğa Bilimleri Fakültesi, Biyomedikal Mühendisliği Bölümü | en_US |
dc.authorid | 0000-0002-5700-3515 | en_US |
dc.identifier.volume | 28 | en_US |
dc.identifier.issue | 5 | en_US |
dc.identifier.startpage | 756 | en_US |
dc.identifier.endpage | 762 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.5137/1019-5149.JTN.21036-17.1 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.identifier.scopusquality | Q3 | en_US |