Basit öğe kaydını göster

dc.contributor.authorKaraman Erdur, Sevil
dc.contributor.authorDemirci, Göktuğ
dc.contributor.authorDikkaya, Funda
dc.contributor.authorKocabora, Mehmet Selim
dc.contributor.authorÖzsütçü, Mustafa
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T20:03:01Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T20:03:01Z
dc.date.issued2018en_US
dc.identifier.citationKaraman Erdur, S., Demirci, G., Dikkaya, F.,Kocabora, M. ve Özsütçü, M. (2018). Comparison of central corneal thickness with ultrasound pachymetry, noncontact specular microscopy and spectral domain optical coherence tomography. Seminars in Ophthalmology, 33(6), 782-787. https://dx.doi.org/10.1080/08820538.2018.1448091en_US
dc.identifier.issn0882-0538
dc.identifier.issn1744-5205
dc.identifier.urihttps://dx.doi.org/10.1080/08820538.2018.1448091
dc.identifier.urihttps://hdl.handle.net/20.500.12511/3787
dc.descriptionWOS: 000444817100007en_US
dc.descriptionPubMed ID: 29509052en_US
dc.description.abstractBackground: To determine the agreement of central corneal thickness (CCT) measurements taken with ultrasonic pachymetry (USP), spectral domain optical coherence tomography (SD-OCT) and noncontact specular microscopy (NSM). Methods: A prospective, observational, cross-sectional study was performed in the outpatient ophthalmology clinic. CCT was measured in a total of 147 eyes of 147 consecutive healthy patients with USP, NSM, and SD-OCT. Same examiner performed all examinations. Bland-Altman plots were used to evaluate the agreement between instruments. Results: The average CCT values obtained by USP, NSM, and SD-OCT were 555 +/- 37 mu m, 554 +/- 34 mu m, and 546 +/- 34 mu m, respectively. There was a strong correlation between instruments: USP with SD-OCT (r = 0.937, p <0.01), USP with NSM (r = 0.943, p <0.01) SD-OCT with NSM (r = 0.975, p <0.01) for CCT. The mean differences (lower/upper limit of agreement) for CCT measurements were -10 +/- 12.9 pm (15.28/-35.28) between SD-OCT and USP-8.1 +/- 7.7 pm (7/-23.2) between SD-OCT and NSM, and 1.8 +/- 12.3 pm (25.9/-22.3) between USP and NSM. Conclusions: USP and NSM were found to have comparable CCT measurements and these two methods can be used correspondingly. However, CCT measurements by SD-OCT were lower when compared to other methods.en_US
dc.language.isoengen_US
dc.publisherTaylor & Francis Incen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectCorneal Thicknessen_US
dc.subjectGlaucomaen_US
dc.subjectOptical Coherence Tomographyen_US
dc.subjectPachymetryen_US
dc.subjectSpecular Microscopyen_US
dc.titleComparison of central corneal thickness with ultrasound pachymetry, noncontact specular microscopy and spectral domain optical coherence tomographyen_US
dc.typearticleen_US
dc.relation.ispartofSeminars in Ophthalmologyen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalıen_US
dc.authorid0000-0001-9829-7268en_US
dc.authorid0000-0002-5079-4713en_US
dc.authorid0000-0003-2312-2521en_US
dc.authorid0000-0001-5335-3860en_US
dc.authorid0000-0001-8954-5055en_US
dc.identifier.volume33en_US
dc.identifier.issue6en_US
dc.identifier.startpage782en_US
dc.identifier.endpage787en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1080/08820538.2018.1448091en_US
dc.identifier.wosqualityQ3en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster