Measurement of photon interaction parameters of high-performance polymers and their composites

Thumbnail

View/Open

Tam Metin / Full Text (2.390Mb)

Access

info:eu-repo/semantics/openAccess

Date

2018

Author

Büyükyıldız, Mehmet
Taşdelen, Mehmet Atilla
Karabul, Yaşar
Beker, Mustafa Çağlar
İçelli, Orhan
Boydaş, Elif

Metadata

Show full item record

Citation

Büyükyıldız, M., Taşdelen, M., Karabul, Y., Beker, M. Ç., İçelli, O. ve Boydaş, E. (2018). Measurement of photon interaction parameters of high-performance polymers and their composites. Radiation Effects and Defects in Solids, 173(5-6), 474-488. https://dx.doi.org/10.1080/10420150.2018.1477155

Abstract

In the present study, commercially important high-performance polymers and their composites have been investigated with respect to photon interactions as means of mass attenuation coefficient (/), mean free path (MFP), half-value layer (HVL), effective atomic number (Z(eff)), effective electron density (N-eff), and energy absorption and exposure buildup factors (EABF and EBF) at different photon energies. For this purpose, sample plates were prepared by extrusion and injection techniques using polyethersulfone, polyetherimide, acrylonitrile butadiene styrene copolymer, polyamide 66, polyphthalamide, and polypropylene copolymers as high-performance polymers and glass and carbon fibers as reinforcement. The (/) s of the materials were measured at 81 and 356keV photon energies to determine MFP, HVL, Z(eff), and N-eff. The theoretical values of these parameters were calculated via ZXCOM, WinXCom and Monte Carlo N-Particle simulation code (MCNP), and a good agreement was obtained between WinXCom-MCNP and MCNP-Exp. Finally, EABFs and EBFs of the samples were calculated up to around 40 MFP in the energy region 0.015-15MeV and significant variations were observed in the continuous energy and MFP regions.

WoS Q Kategorisi

Q4

xmlui.dri2xhtml.METS-1.0.item-scopusquality

Q3

Source

Radiation Effects and Defects in Solids

Volume

173

Issue

5-6

URI

https://dx.doi.org/10.1080/10420150.2018.1477155
https://hdl.handle.net/20.500.12511/3736

Collections

  • Diğer Yayınlar Koleksiyonu [204]
  • Scopus İndeksli Yayınlar Koleksiyonu [5794]
  • WoS İndeksli Yayınlar Koleksiyonu [5972]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Guide | Contact |

DSpace@Medipol

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsInstitution AuthorORCIDTitlesSubjectsTypeLanguageDepartmentCategoryWoS Q ValueScopus Q ValuePublisherAccess TypeThis CollectionBy Issue DateAuthorsInstitution AuthorORCIDTitlesSubjectsTypeLanguageDepartmentCategoryWoS Q ValueScopus Q ValuePublisherAccess Type

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide || Library || İstanbul Medipol University || OAI-PMH ||

Kütüphane ve Dokümantasyon Daire Başkanlığı, İstabul, Turkey
If you find any errors in content, please contact: [email protected]

Creative Commons License
DSpace@Medipol by İstanbul Medipol University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Medipol:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.