Basit öğe kaydını göster

dc.contributor.authorTuzcu, Volkan
dc.contributor.authorGül, Enes Elvin
dc.contributor.authorKaracan, Mehmet
dc.contributor.authorKamalı, Hacer
dc.contributor.authorÇelik, Nida
dc.contributor.authorAkdeniz, Celal
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T20:02:26Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T20:02:26Z
dc.date.issued2017en_US
dc.identifier.citationTuzcu, V., Gül, E. E., Karacan, M., Kamalı, H., Çelik, N. ve Akdeniz, C. (2017). Comparison of 6-mm versus 8-mm-tip cryoablation catheter for the treatment of atrioventricular nodal reentrant tachycardia in children: A prospective study. Pediatric Cardiology, 38(6), 1220-1225. https://dx.doi.org/10.1007/s00246-017-1648-zen_US
dc.identifier.issn0172-0643
dc.identifier.issn1432-1971
dc.identifier.urihttps://dx.doi.org/10.1007/s00246-017-1648-z
dc.identifier.urihttps://hdl.handle.net/20.500.12511/3648
dc.descriptionWOS: 000405798800018en_US
dc.descriptionPubMed ID: 28612086en_US
dc.description.abstractDue to its safety profile, cryoablation (Cryo) for atrioventricular nodal reentrant tachycardia (AVNRT) is more commonly preferred over radiofrequency (RF) ablation in children in recent years. Recent studies demonstrated high long-term success rates comparable to radiofrequency ablation. The aim of this prospective study was to compare the efficacy and safety of an 8-mm-tip versus 6-mm-tip Cryo catheter in the treatment of AVNRT in children. A total of 125 consecutive patients over 10 years of age with AVNRT were included. EnSite system (St. JudeMedical, St Paul, MN, USA) was used to reduce or eliminate fluoroscopy. The acute procedural success was 100% in both groups. The prodecure duration for the 8-mm-tip group was shorter (151.6 +/- 63.2 vs. 126.6 +/- 36.7 min, p < 0.01, respectively). Fluoroscopy was used in only 7 patients. The mean follow-up duration was 14.6 +/- 8.4 months (median 13.5 months, min. 3 months and max. 27 months). The recurrence rate for AVNRT was also comparable between the two groups (6-mm tip: 9.6 vs. 8-mm tip: 8%). Cryo of AVNRT is a safe and effective procedure with comparable acute and mid-term follow-up success rates using 6-mm and 8-mm-tip catheters in children. In addition, procedure duration is shorter with an 8-mm-tip Cryo catheter.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCryoablationen_US
dc.subjectAVNRTen_US
dc.subjectCatheter Tipen_US
dc.subjectRecurrenceen_US
dc.titleComparison of 6-mm versus 8-mm-tip cryoablation catheter for the treatment of atrioventricular nodal reentrant tachycardia in children: A prospective studyen_US
dc.typearticleen_US
dc.relation.ispartofPediatric Cardiologyen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalıen_US
dc.authorid0000-0001-9008-4997en_US
dc.authorid0000-0002-4375-2881en_US
dc.authorid0000-0002-2947-6120en_US
dc.authorid0000-0003-1710-6867en_US
dc.authorid0000-0002-8647-6055en_US
dc.identifier.volume38en_US
dc.identifier.issue6en_US
dc.identifier.startpage1220en_US
dc.identifier.endpage1225en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1007/s00246-017-1648-zen_US
dc.identifier.wosqualityQ3en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster