Basit öğe kaydını göster

dc.contributor.authorEkici, Kemal
dc.contributor.authorKaya Pepele, Eda
dc.contributor.authorYaprak, Bahaddin
dc.contributor.authorTemelli, Öztun
dc.contributor.authorEraslan, Aysun Fatma
dc.contributor.authorKüçük, Nadir
dc.contributor.authorYıldırım Altınok, Ayşe
dc.contributor.authorAltınok Süt, Pelin
dc.contributor.authorAlpak, Özlem D.
dc.contributor.authorÇolak, Cemil
dc.contributor.authorMayadağlı, Alpaslan
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T20:01:42Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T20:01:42Z
dc.date.issued2016en_US
dc.identifier.citationEkici, K., Kaya Pepele, E., Yaprak, B., Temelli, Ö., Eraslan, A. F., Küçük, N. ... Mayadağlı, A. (2016). Dosimetric comparison of helical tomotherapy, intensity-modulated radiation therapy, volumetric-modulated arc therapy, and 3-dimensional conformal therapy for the treatment of T1N0 glottic cancer. Medical Dosimetry, 41(4), 329-333. https://dx.doi.org/10.1016/j.meddos.2016.08.002en_US
dc.identifier.issn0958-3947
dc.identifier.issn1873-4022
dc.identifier.urihttps://dx.doi.org/10.1016/j.meddos.2016.08.002
dc.identifier.urihttps://hdl.handle.net/20.500.12511/3409
dc.descriptionWOS: 000389011500012en_US
dc.descriptionPubMed ID: 27765542en_US
dc.description.abstractVarious radiotherapy planning methods for T1N0 laryngeal cancer have been proposed to decrease normal tissue toxicity. We compare helical tomotherapy (HT), linac-based intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and 3-D conformal radiotherapy (3D-CRT) techniques for T1N0 laryngeal cancer. Overall, 10 patients with T1N0 laryngeal cancer were selected and evaluated. Furthermore, 10 radiotherapy treatment plans have been created for all 10 patients, including HT, IMRT, VMAT, and 3D-CRT. IMRT, VMAT, and HT plans vs 3D-CRT plans consistently provided superior planning target volume (PTV) coverage. Similar target coverage was observed between the 3 IMRT modalities. Compared with 3D-CRT, IMRT, HT, and VMAT significantly reduced the mean dose to the carotid arteries. VMAT resulted in the lowest mean dose to the submandibular and thyroid glands. Compared with 3D-CRT, IMRT, HT, and VMAT significantly increased the maximum dose to the spinal cord It was observed that the 3 IMRT modalities studied showed superior target coverage with less variation between each plan in comparison with 3D-CRT. The 3D-CRT plans performed better at the Dmax of the spinal cord. Clinical investigation is warranted to determine if these treatment approaches would translate into a reduction in radiation therapy-induced toxicities.en_US
dc.language.isoengen_US
dc.publisherElsevier Science Incen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectLarynx Canceren_US
dc.subjectHelical Tomotherapyen_US
dc.subjectVolumetric Arc Therapyen_US
dc.subjectIntensity-Modulated Radiotherapyen_US
dc.titleDosimetric comparison of helical tomotherapy, intensity-modulated radiation therapy, volumetric-modulated arc therapy, and 3-dimensional conformal therapy for the treatment of T1N0 glottic canceren_US
dc.typearticleen_US
dc.relation.ispartofMedical Dosimetryen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Radyasyon Onkolojisi Ana Bilim Dalıen_US
dc.identifier.volume41en_US
dc.identifier.issue4en_US
dc.identifier.startpage329en_US
dc.identifier.endpage333en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.meddos.2016.08.002en_US
dc.identifier.wosqualityQ4en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster