Basit öğe kaydını göster

dc.contributor.authorJurkovic, Ines Ana
dc.contributor.authorKoçak Uzel, Esengül
dc.contributor.authorMohamed, Abdallah Sherif Radwan
dc.contributor.authorLavdas, Eleftherios
dc.contributor.authorStathakis, Sotirios
dc.contributor.authorPapanikolaou, Nikos
dc.contributor.authorFuller, Clifton David
dc.contributor.authorMavroidis, Panayiotis
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:58:35Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:58:35Z
dc.date.issued2018en_US
dc.identifier.citationJurkovic, I. A., Koçak-Uzel, E., Mohamed, A. S. R., Lavdas, E., Stathakis, S., Papanikolaou, N ... Mavroidis, P. (2018). Dosimetric and radiobiological evaluation of patient setup accuracy in head-and-neck radiotherapy using daily computed tomography-on-rails-based corrections. Journal of Medical Physics, 43(1), 28-40. https://dx.doi.org/10.4103/jmp.JMP_113_17en_US
dc.identifier.issn0971-6203
dc.identifier.issn1998-3913
dc.identifier.urihttps://dx.doi.org/10.4103/jmp.JMP_113_17
dc.identifier.urihttps://hdl.handle.net/20.500.12511/3196
dc.descriptionWOS: 000427452000005en_US
dc.descriptionPubMed ID: 29628631en_US
dc.description.abstractIntroduction: This study evaluates treatment plans aiming at determining the expected impact of daily patient setup corrections on the delivered dose distribution and plan parameters in head-and-neck radiotherapy. Materials and Methods: In this study, 10 head-and-neck cancer patients are evaluated. For the evaluation of daily changes of the patient internal anatomy, image-guided radiation therapy based on computed tomography (CT)-on-rails was used. The daily-acquired CT-on-rails images were deformedly registered to the CT scan that was used during treatment planning. Two approaches were used during data analysis ("cascade" and "one-to-all"). The dosimetric and radiobiological differences of the dose distributions with and without patient setup correction were calculated. The evaluation is performed using dose-volume histograms; the biologically effective uniform dose (sic) and the complication-free tumor control probability (P+) were also calculated. The dose-response curves of each target and organ at risk (OAR), as well as the corresponding P+ curves, were calculated. Results: The average difference for the "one-to-all" case is 0.6 +/- 1.8 Gy and for the "cascade" case is 0.5 +/- 1.8 Gy. The value of P+ was lowest for the cascade case (in 80% of the patients). Discussion: Overall, the lowest P-I is observed in the one-to-all cases. Dosimetrically, CT-on-rails data are not worse or better than the planned data. Conclusions: The differences between the evaluated "one-to-all" and "cascade" dose distributions were small. Although the differences of those doses against the "planned" dose distributions were small for the majority of the patients, they were large for given patients at risk and OAR.en_US
dc.description.sponsorshipAndrew Sabin Family Foundation; National Institutes of Health (NIH); National Institute for Dental and Craniofacial Research Award [1R01DE025248-01/R56DE025248-01]; National Science Foundation (NSF), Division of Mathematical Sciences, Joint NIH/NSF Initiative on Quantitative Approaches to Biomedical Big Data (QuBBD) Grant [NSF 1557679]; NIH Big Data to Knowledge (BD2K) Program of the National Cancer Institute (NCI) Early Stage Development of Technologies in Biomedical Computing, Informatics, and Big Data Science Award [1R01CA214825-01]; NCI Early Phase Clinical Trials in Imaging and Image-Guided Interventions Program [1R01CA218148-01]; NIH/NCI Cancer Center Support Grant (CCSG) Pilot Research Program Award from the UT MD Anderson CCSG Radiation Oncology and Cancer Imaging Program [P30CA016672]; NIH/NCI Head and Neck Specialized Programs of Research Excellence (SPORE) Developmental Research Program Award [P50 CA097007-10]; Elekta ABen_US
dc.description.sponsorshipThis research is supported by the Andrew Sabin Family Foundation; Dr. Fuller is a Sabin Family Foundation Fellow. Dr. Fuller receives funding and salary support from the National Institutes of Health (NIH), including: the National Institute for Dental and Craniofacial Research Award (1R01DE025248-01/R56DE025248-01); a National Science Foundation (NSF), Division of Mathematical Sciences, Joint NIH/NSF Initiative on Quantitative Approaches to Biomedical Big Data (QuBBD) Grant (NSF 1557679); the NIH Big Data to Knowledge (BD2K) Program of the National Cancer Institute (NCI) Early Stage Development of Technologies in Biomedical Computing, Informatics, and Big Data Science Award (1R01CA214825-01); NCI Early Phase Clinical Trials in Imaging and Image-Guided Interventions Program (1R01CA218148-01); an NIH/NCI Cancer Center Support Grant (CCSG) Pilot Research Program Award from the UT MD Anderson CCSG Radiation Oncology and Cancer Imaging Program (P30CA016672) and an NIH/NCI Head and Neck Specialized Programs of Research Excellence (SPORE) Developmental Research Program Award (P50 CA097007-10). Dr. Fuller has received direct industry grant support and travel funding from Elekta AB and served as a consultant for Philips Medical Systems.en_US
dc.language.isoengen_US
dc.publisherMedknow Publicationsen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 Unported*
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/*
dc.subjectBiologically Effective Uniform Doseen_US
dc.subjectComputed Tomography-on-Railsen_US
dc.subjectDose-Volume Histogramen_US
dc.subjectRadiobiological Measuresen_US
dc.subjectTreatment Planningen_US
dc.subjectTumor Controlen_US
dc.titleDosimetric and radiobiological evaluation of patient setup accuracy in head-and-neck radiotherapy using daily computed tomography-on-rails-based correctionsen_US
dc.typearticleen_US
dc.relation.ispartofJournal of Medical Physicsen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Radyasyon Onkolojisi Ana Bilim Dalıen_US
dc.identifier.volume43en_US
dc.identifier.issue1en_US
dc.identifier.startpage28en_US
dc.identifier.endpage40en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.4103/jmp.JMP_113_17en_US
dc.identifier.scopusqualityQ3en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster

info:eu-repo/semantics/openAccess
Aksi belirtilmediği sürece bu öğenin lisansı: info:eu-repo/semantics/openAccess