Show simple item record

dc.contributor.authorKara, Adnan
dc.contributor.authorÇelik, Haluk
dc.contributor.authorBankaoğlu, Müjdat
dc.contributor.authorÖç, Yunus
dc.contributor.authorBülbül, Murat
dc.contributor.authorSügün, Tahir Sadık
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:58:14Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:58:14Z
dc.date.issued2016en_US
dc.identifier.citationKara, A., Çelik, H., Bankaoğlu, M., Öç, Y., Bülbül, M. ve Sügün, T. S. (2016). Ultrasonic evaluation of the flexor pollicis longus tendon following volar plate fixation for distal radius fractures. Journal Of Hand Surgery-American Volume, 41(3), 374-380. https://dx.doi.org/10.1016/j.jhsa.2015.11.022en_US
dc.identifier.issn0363-5023
dc.identifier.issn1531-6564
dc.identifier.urihttps://dx.doi.org/10.1016/j.jhsa.2015.11.022
dc.identifier.urihttps://hdl.handle.net/20.500.12511/3131
dc.descriptionWOS: 000372018800007en_US
dc.descriptionPubMed ID: 26787412en_US
dc.description.abstractPurpose To evaluate with ultrasound the thickness of the flexor pollicis longus (FPL) tendon and its relationship to the volar locking plate after the fixation of distal radius fractures. Methods We evaluated 27 type C2 and C3 distal radius fractures with ultrasound to evaluate damage to the FPL tendon after volar plate fixation. The thickness of the FPL tendon and its distance to the volar plate in the involved wrists and to the volar rim in the contralateral uninjured wrist were measured on sonograms taken 12 months postoperatively. Measurements of the involved wrists were compared with those of the intact wrists. Results The mean plate-tendon distance in the involved wrist was considerably shorter than the mean volar rim-tendon distance in the intact wrist, and the FPL tendon was considerably thicker in the involved wrist than in the intact wrist. Conclusions In distal radial fractures treated with volar locking plates, increases in the thickness of the FPL tendon and a consequent decrease in the distance between the tendon and the plate can be determined with ultrasonography. This finding is a warning that asymptomatic tenosynovitis may eventually cause tendon ruptures.en_US
dc.language.isoengen_US
dc.publisherW B Saunders Co-Elsevier Incen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectDistal Radius Fractureen_US
dc.subjectFlexor Tendon Complicationsen_US
dc.subjectUltrasonic Evaluationen_US
dc.subjectVolar Platingen_US
dc.subjectWatershed Lineen_US
dc.titleUltrasonic evaluation of the flexor pollicis longus tendon following volar plate fixation for distal radius fracturesen_US
dc.typearticleen_US
dc.relation.journalJournal Of Hand Surgery-American Volumeen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Ortopedi ve Travmatoloji Ana Bilim Dalıen_US
dc.identifier.volume41en_US
dc.identifier.issue3en_US
dc.identifier.startpage374en_US
dc.identifier.endpage380en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.jhsa.2015.11.022en_US