A new mini-external fixator for treating hallux valgus: A preclinical, biomechanical study

Thumbnail

View/Open

Tam Metin / Full Text (1.396Mb)

Access

info:eu-repo/semantics/embargoedAccess

Date

2016

Author

Erdil, Mehmet
Ceylan, Hasan Hüseyin
Polat, Gökhan
Kara, Deniz
Bozdağ, Ergün
Sünbüloğlu, Emin

Metadata

Show full item record

Citation

Erdil, M., Ceylan, H. H., Polat, G., Kara, D., Kara, D. ve Sünbüloğlu, E. (2016). A new mini-external fixator for treating hallux valgus: A preclinical, biomechanical study. Journal Of Foot & Ankle Surgery, 55(1), 35-38. https://dx.doi.org/10.1053/j.jfas.2015.04.018

Abstract

Proximal metatarsal osteotomy is the most effective technique for correcting hallux valgus deformities, especially in metatarsus primus varus. However, these surgeries are technically demanding and prone to complications, such as nonunion, implant failure, and unexpected extension of the osteotomy to the tarsometatarsal joint. In a preclinical study, we evaluated the biomechanical properties of the fixator and compared it with compression screws for treating hallux valgus with a proximal metatarsal osteotomy. Of 18 metatarsal composite bone models proximally osteotomized, 9 were fixed with a headless compression screw and 9 with the mini-external fixator. A dorsal angulation of 10 degrees and displacement of 10 mm were defined as the failure threshold values. Construct stiffness and the amount of interfragmentary angulation were calculated at various load cycles. All screw models failed before completing 1000 load cycles. In the fixator group, only 2 of 9 models (22.2%) failed before 1000 cycles, both between the 600th and 700th load cycles. The stability of fixation differed significantly between the groups (p < .001). The stability provided by the mini-external fixator was superior to that of compression screw fixation. Additional testing of the fixator is indicated.

WoS Q Kategorisi

Q4

xmlui.dri2xhtml.METS-1.0.item-scopusquality

Q2

Source

Journal Of Foot & Ankle Surgery

Volume

55

Issue

1

URI

https://dx.doi.org/10.1053/j.jfas.2015.04.018
https://hdl.handle.net/20.500.12511/3123

Collections

  • Makale Koleksiyonu [3255]
  • PubMed İndeksli Yayınlar Koleksiyonu [3553]
  • Scopus İndeksli Yayınlar Koleksiyonu [5461]
  • WoS İndeksli Yayınlar Koleksiyonu [5651]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Guide | Contact |

[email protected]

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsInstitution AuthorORCIDTitlesSubjectsTypeLanguageDepartmentCategoryWoS Q ValueScopus Q ValuePublisherAccess TypeThis CollectionBy Issue DateAuthorsInstitution AuthorORCIDTitlesSubjectsTypeLanguageDepartmentCategoryWoS Q ValueScopus Q ValuePublisherAccess Type

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide || Library || İstanbul Medipol University || OAI-PMH ||

Kütüphane ve Dokümantasyon Daire Başkanlığı, İstabul, Turkey
If you find any errors in content, please contact: [email protected]

Creative Commons License
[email protected] by İstanbul Medipol University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

[email protected]:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.