Basit öğe kaydını göster

dc.contributor.authorKılınç, Bekir Eray
dc.contributor.authorKara, Adnan
dc.contributor.authorÇelik, Haluk
dc.contributor.authorÖç, Yunus
dc.contributor.authorÇamur, Savaş
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:58:07Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:58:07Z
dc.date.issued2016en_US
dc.identifier.citationKılınç, B. E., Kara, A., Çelik, H., Öç, Y. ve Çamur, S. (2016). Evaluation of the accuracy of lachman and anterior drawer tests with KT1000 in the follow-up of anterior cruciate ligament surgery. Journal Of Exercise Rehabilitation, 12(4), 363-367. https://dx.doi.org/10.12965//jer.1632622.311en_US
dc.identifier.issn2288-176X
dc.identifier.issn2288-1778
dc.identifier.urihttps://dx.doi.org/10.12965//jer.1632622.311
dc.identifier.urihttps://hdl.handle.net/20.500.12511/3110
dc.descriptionWOS: 000446917800017en_US
dc.descriptionPubMed ID: 27656635en_US
dc.description.abstractLigament laxity measurement is clinically valuable to diagnose the injury and also to compare the laxity before and after surgical procedure. The aim of the study was to compare the accuracy of the Lachman and Anterior Drawer Tests to evaluate the knee examination with the KT1000 arthrometer after the anterior cruciate ligament (ACL) surgery in early follow-up period. Fourty ACL reconstructed knees were examined with the Lachman and Anterior Drawer Tests, and KT1000 arthrometer with compariable intact knee of the same patients. Physical emanination findings were compared with the KT1000 arthrometer with each power. Spearman correlation and receiver operating characteristic (ROC) analysis were used for the evaluation of relations between parameters. Significance was evaluated in P<0.1 and P<0.05. The mean age was 28.18 +/- 6.21 yr, and the mean follow-up was 23.09 +/- 9.08 months. The mean KT1000 measurements of 40 operated knees state at 6.8, 9.1, 13.6 kg and maxium anterior displacement forces were 4.9, 6.7, 8.7, and 11.9 mm, respectively. The same values for the same acting forces of intact knees were 4.2, 5.9, 7.8, and 10.2, respectively. In Spearman's correlation and ROC analysis at 13.6-kg power on KT1000 arthrometer statistically matched with pyhsical examinations (P<0.1, P<0.01). In our study, correlation of physical examinations with KT1000 arthrometer is a worthy evaluation technique that can be added to examination of ACL reconstructed knee to control with inexperinced examiners' findings. We suggest that at 13.6-kg power with KT1000 arthrometer findings perfectly match the Lachman and Anterior Drawer Tests of the knee.en_US
dc.language.isoengen_US
dc.publisherKorean Soc Exercise Rehabilitationen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial 4.0 International*
dc.rightshttps://creativecommons.org/licenses/by-nc/4.0/*
dc.subjectLachman Testen_US
dc.subjectKT1000 Arthrometeren_US
dc.subjectAnterior Drawer Testen_US
dc.subjectAnterior Cruciate Ligamenten_US
dc.subjectAnterior Displacementen_US
dc.subjectKnee Examinationen_US
dc.titleEvaluation of the accuracy of lachman and anterior drawer tests with KT1000 in the follow-up of anterior cruciate ligament surgeryen_US
dc.typearticleen_US
dc.relation.ispartofJournal Of Exercise Rehabilitationen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Ortopedi ve Travmatoloji Ana Bilim Dalıen_US
dc.identifier.volume12en_US
dc.identifier.issue4en_US
dc.identifier.startpage363en_US
dc.identifier.endpage367en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.12965//jer.1632622.311en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster