• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   [email protected]
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
  •   [email protected]
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Implantation of looped epicardial cardioverter defibrillator coil on the surface of the right ventricular outflow tract

Thumbnail

View/Open

Tam Metin / Full Text (466.4Kb)

Access

info:eu-repo/semantics/embargoedAccess

Date

2015

Author

Özyüksel, Arda
Ersoy, Cihangir
Akdeniz, Celal
Akçevin, Atıf
Türkoǧlu, Halil
Tuzcu, Volkan

Metadata

Show full item record

Citation

Özyüksel, A., Ersoy, C., Akdeniz, C., Akçevin, A., Türkoǧlu, H. ve Tuzcu, V. (2015). Implantation of looped epicardial cardioverter defibrillator coil on the surface of the right ventricular outflow tract. Journal of Cardiac Surgery, 30(4), 376-380. https://dx.doi.org/10.1111/jocs.12525

Abstract

BackgroundWe present the early results of looped epicardial cardioverter defibrillator coil implantation on the anterior surface of right ventricular outflow tract in infants and children. MethodsPatients with a surgical history of an epicardial implantable cardioverter defibrillator system between 2013 and 2014 were included in the study. Patient age, gender, body weight, indications for a cardioverter defibrillator system implantation, defibrillation threshold values, and defibrillation therapies were retrospectively evaluated. ResultsThere were eight patients with a mean age of 4.42.9 years and a mean body weight of 19.5 +/- 11.7kg. Five of the patients had been diagnosed with long QT syndrome, one patient had been diagnosed with genetic channelopathy and noncompaction of the left ventricle, and two patients had been diagnosed with univentricle physiology. The implantable cardioverter defibrillator system was composed of pace-sense leads, an abdominal active can, and a defibrillation coil placed below the pulmonary valve annulus on the anterior surface of the heart. The mean defibrillation threshold was 6.6 +/- 2.3 joules. There were four appropriate therapies in two patients in a mean follow-up of 9 +/- 6.5 months. ConclusionThe significantly low defibrillation thresholds with the defibrillation coils located below the pulmonary valve annulus are encouraging. However, a larger patient series will be necessary to evaluate the safety and reliability of this technique.

WoS Q Kategorisi

Q4

xmlui.dri2xhtml.METS-1.0.item-scopusquality

Q2

Source

Journal of Cardiac Surgery

Volume

30

Issue

4

URI

https://dx.doi.org/10.1111/jocs.12525
https://hdl.handle.net/20.500.12511/3001

Collections

  • Makale Koleksiyonu [3170]
  • PubMed İndeksli Yayınlar Koleksiyonu [3490]
  • Scopus İndeksli Yayınlar Koleksiyonu [5326]
  • WoS İndeksli Yayınlar Koleksiyonu [5545]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Guide | Contact |

[email protected]

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsInstitution AuthorORCIDTitlesSubjectsTypeLanguageDepartmentCategoryWoS Q ValueScopus Q ValuePublisherAccess TypeThis CollectionBy Issue DateAuthorsInstitution AuthorORCIDTitlesSubjectsTypeLanguageDepartmentCategoryWoS Q ValueScopus Q ValuePublisherAccess Type

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide || Library || İstanbul Medipol University || OAI-PMH ||

Kütüphane ve Dokümantasyon Daire Başkanlığı, İstabul, Turkey
If you find any errors in content, please contact: [email protected]

Creative Commons License
[email protected] by İstanbul Medipol University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

[email protected]:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.