Basit öğe kaydını göster

dc.contributor.authorToz, Tuğba
dc.contributor.authorTuncer, Safa
dc.contributor.authorÖztürk Bozkurt, Funda
dc.contributor.authorKara Tuncer, Aysun
dc.contributor.authorGözükara Bağ, Harika
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:57:15Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:57:15Z
dc.date.issued2015en_US
dc.identifier.citationToz, T., Tuncer, S., Öztürk Bozkurt, F., Kara Tuncer, A. ve Gözükara Bağ, H. (2015). The effect of bulk-fill flowable composites on the fracture resistance and cuspal deflection of endodontically treated premolars. Journal of Adhesion Science and Technology, 29(15), 1581-1592. https://dx.doi.org/10.1080/01694243.2015.1037381en_US
dc.identifier.issn0169-4243
dc.identifier.issn1568-5616
dc.identifier.urihttps://dx.doi.org/10.1080/01694243.2015.1037381
dc.identifier.urihttps://hdl.handle.net/20.500.12511/2935
dc.descriptionWOS: 000354532700006en_US
dc.description.abstractThe aim of this study was to evaluate the effect of bulk-fill flowable composites on cuspal deflection and fracture resistance of endodontically treated teeth. Forty-two maxillary premolars were subjected to endodontic treatment followed by the preparation of mesioocclusodistal cavities. Teeth were divided into six groups according to restorative materials as follows: Group 1: Clearfil Majesty Flow and Clearfil Majesty Posterior; Group 2: Venus Bulk Fill and Clearfil Majesty Posterior; Group 3: Clearfil Majesty Posterior; Group 4: Vertise Flow and Clearfil Majesty Posterior; Group 5: SDR and Clearfil Majesty Posterior; and Group 6: x-tra base and Clearfil Majesty Posterior. A single-step self-etch adhesive (OptiBond All-in-One) was applied to all groups, except Group 4. The cavities were restored with a centripetal incremental insertion technique and flowable composites using a 2-mm-thick base material, except for Group 3. The distance between cusp tips was measured before and after the cavity preparations, after the restorations, and after thermal cyclus with a digital micrometer. After measuring, each tooth was subjected to compressive loading with a stainless steel ball (4mm diameter) perpendicular to the occlusal surface with a crosshead speed of 1mm/min, and mean loads necessary to fracture were recorded in Newtons. The data were statistically analyzed by Kruskal-Wallis test. No statistically significant differences were found between groups in fracture strength or cuspal deflections (p>0.05). Bulk-fill flowable composite bases did not change the cuspal deflection or fracture resistance of endodontically treated teeth, compared with that of a conventional flowable base and conventional resin composite.en_US
dc.language.isoengen_US
dc.publisherTaylor and Francisen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectBulk-fill Compositeen_US
dc.subjectCuspal Deflectionen_US
dc.subjectEndodontically Treated Teethen_US
dc.subjectFracture Resistanceen_US
dc.titleThe effect of bulk-fill flowable composites on the fracture resistance and cuspal deflection of endodontically treated premolarsen_US
dc.typearticleen_US
dc.relation.ispartofJournal of Adhesion Science and Technologyen_US
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Restoratif Diş Tedavisi Ana Bilim Dalıen_US
dc.identifier.volume29en_US
dc.identifier.issue15en_US
dc.identifier.startpage1581en_US
dc.identifier.endpage1592en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1080/01694243.2015.1037381en_US
dc.identifier.wosqualityQ3en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster