Basit öğe kaydını göster

dc.contributor.authorDemirci, Göktuğ
dc.contributor.authorArslan, Banu
dc.contributor.authorÖzsütçü, Mustafa
dc.contributor.authorEliaçık, Mustafa
dc.contributor.authorGülkilik, Gökhan
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:57:00Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:57:00Z
dc.date.issued2014en_US
dc.identifier.citationDemirci, G., Arslan, B., Özsütçü, M., Eliaçık, M. ve Gülkilik, G. (2014). Comparison of photorefraction, autorefractometry and retinoscopy in children. International Ophthalmology, 34(4), 739-746. https://dx.doi.org/10.1007/s10792-013-9864-xen_US
dc.identifier.issn0165-5701
dc.identifier.issn1573-2630
dc.identifier.urihttps://dx.doi.org/10.1007/s10792-013-9864-x
dc.identifier.urihttps://hdl.handle.net/20.500.12511/2875
dc.descriptionWOS: 000341838400003en_US
dc.descriptionPubMed ID: 24114503en_US
dc.description.abstractPhotorefractive devices have been evaluated for their effectiveness in detecting anisometropia, hyperopia, myopia, and astigmatism. We investigated the reliability of Plusoptix S08, the newest photoscreener, and Topcon autorefractometer by comparing them with cycloplegic retinoscopy. Plusoptix S08, cycloplegic retinoscopy, and cycloplegic autorefractometer measurements for 235 eyes of 118 children (59 female, 59 male) with a mean age of 4.9 +/- 2.6 and median age of 5 years (range 1-12) were conducted. The Plusoptix S08 produced the following mean (+/- SD) results-spherical 0.27 +/- 1.64, cylindrical power -0.81 +/- 0.71, axis 89.73 +/- 61.18, and spherical equivalent -0.05 +/- 1.61. The cycloplegic retinoscopy produced the following mean (+/- SD) results-spherical 0.12 +/- 1.35, cylindrical power -0.89 +/- 0.71, axis 92.18 +/- 68.39, and spherical equivalent -0.15 +/- 1.31. The cycloplegic autorefractometer produced the following mean (+/- SD) results-spherical 0.16 +/- 1.44, cylindrical power -0.88 +/- 0.72, axis 90.86 +/- 68.21, and spherical equivalent -0.12 +/- 1.41. This study has shown that cycloplegic autorefractometer and retinoscopy results are similar and Plusoptix S08 is a very safe, easy-to-use and reliable screening method of refraction, especially for ophthalmologists unskilled in retinoscopy. Plusoptix S08 is a useful tool for estimating refraction in patients for whom conventional autorefraction is not an option.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectRetinoscopyen_US
dc.subjectPhotorefractionen_US
dc.subjectAutorefractometryen_US
dc.titleComparison of photorefraction, autorefractometry and retinoscopy in childrenen_US
dc.typearticleen_US
dc.relation.ispartofInternational Ophthalmologyen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Ortopedi ve Travmatoloji Ana Bilim Dalıen_US
dc.authorid0000-0002-5079-4713en_US
dc.authorid0000-0001-8954-5055en_US
dc.authorid0000-0002-2563-2149en_US
dc.identifier.volume34en_US
dc.identifier.issue4en_US
dc.identifier.startpage739en_US
dc.identifier.endpage746en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1007/s10792-013-9864-xen_US
dc.identifier.wosqualityQ3en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster