dc.description.abstractPurpose: The aim of this investigation was to measure the temperature increase due to heat transferred to the implant-bone interface when the abutment screw channel is accessed or a metal-ceramic crown is sectioned buccally with diamond or tungsten carbide bur using an air rotor, with or without irrigation. Materials and Methods: Cobalt-chromium copings were cemented onto straight titanium abutments. The temperature changes during removal of the copings were recorded over a period of 1 minute. Results: The sectioning of coping with diamond bur and without water irrigation generated the highest temperature change at the cervical part of the implant. Conclusion: Both crown removal methods resulted in an increase in temperature at the implant-bone interface. However, this temperature change did not exceed 47 degrees C, the potentially damaging threshold for bone reported in the literature.en_US
dc.language.isoengen_US
dc.publisherQuintessence Publishing Co Incen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectEvaluation of Heaten_US
dc.subjectImplant-Boneen_US
dc.subjectRemoval of Metal Copingsen_US
dc.subjectCemented Onto Titanium Abutmentsen_US
dc.titleEvaluation of heat transfer to the implant-bone interface during removal of metal copings cemented onto titanium abutmentsen_US
dc.typearticleen_US
dc.relation.ispartofInternational Journal Of Prosthodonticsen_US
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi Ana Bilim Dalıen_US
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalıen_US
dc.authorid0000-0003-3347-1151en_US
dc.identifier.volume29en_US
dc.identifier.issue3en_US
dc.identifier.startpage290en_US
dc.identifier.endpage292en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.11607/ijp.4561en_US
dc.identifier.wosqualityQ4en_US
dc.identifier.scopusqualityQ1en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster