Basit öğe kaydını göster

dc.contributor.authorEliaçık, Mustafa
dc.contributor.authorErdur Karaman, Sevil
dc.contributor.authorGülkılık, Gökhan
dc.contributor.authorÖzsütçü, Mustafa
dc.contributor.authorAras, Cengiz
dc.contributor.authorBayramlar, Hüseyin
dc.contributor.authorAslan Anıl, Cemile
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:56:00Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:56:00Z
dc.date.issued2016en_US
dc.identifier.citationEliaçık, M., Erdur Karaman, S., Gülkılık, G., Özsütçü, M., Aras, C., Bayramlar, H. ... Aslan Anıl, C. (2016). Anterior segment optical coherence tomography assessment after laser capsulotomy in pseudophakic eyes with pseudoexfoliation. Eye & Contact Lens-Science And Clinical Practice, 42(5), 318-321. https://dx.doi.org/10.1097/ICL.0000000000000185en_US
dc.identifier.issn1542-2321
dc.identifier.issn1542-233X
dc.identifier.urihttps://dx.doi.org/10.1097/ICL.0000000000000185
dc.identifier.urihttps://hdl.handle.net/20.500.12511/2520
dc.descriptionWOS: 000384001400010en_US
dc.descriptionPubMed ID: 26322919en_US
dc.description.abstractPurpose:To assess changes in anterior-chamber depth (ACD) and angle width after neodymium:yttrium aluminum garnet (Nd:YAG) laser capsulotomy pseudophakia in eyes with pseudoexfoliation (PEX).Methods:This prospective and interventional case series study included 25 pseudophakic eyes of 25 patients with PEX and 26 pseudophakic eyes of 26 patients without PEX scheduled for Nd:YAG laser capsulotomy in a single institution. Anterior-chamber depth and angle width were measured with anterior segment optical coherence tomography before and three days after Nd:YAG laser capsulotomy. Preoperative and postoperative measurements of ACD and angle width included the angle opening distance (AOD), measured as the perpendicular distance from the trabecular meshwork at 500 and 750 mm anterior to the scleral spur to the anterior iris surface (AOD500 and AOD750, respectively) and anterior-chamber angle (ACA) in the nasal and temporal quadrants. Main outcome measures were the changes in ACD and angle width parameters.Results:The mean ACD, AOD500, AOD750, and ACA (nasal and temporal) measurements were 3.670.12 mm, 0.63 +/- 0.05 mm and 0.65 +/- 0.05 mm, 0.67 +/- 0.06 mm and 0.77 +/- 0.04 mm, 35.25 +/- 1.69 degrees and 35.37 +/- 1.68 degrees in eyes with PEX and 3.73 +/- 0.11 mm, 0.6 +/- 0.05 mm and 0.63 +/- 0.05 mm, 0.66 +/- 0.06 mm and 0.74 +/- 0.06 mm, 34.24 +/- 1.6 degrees and 34.6 +/- 1.47 degrees in control eyes, respectively (P>0.05 for all). After Nd:YAG laser capsulotomy, mean ACD, AOD500, AOD750, and ACA (nasal and temporal) measurements were 3.76 +/- 0.09 mm, 0.73 +/- 0.05 mm and 0.76 +/- 0.05 mm, 0.75 +/- 0.06 mm and 0.87 +/- 0.04 mm, 36.82 +/- 1.46 degrees and 35.06 +/- 1.52 degrees in eyes with PEX and 3.77 +/- 0.1 mm, 0.68 +/- 0.06 mm and 0.72 +/- 0.06 mm, 0.72 +/- 0.05 mm and 0.84 +/- 0.06 mm, 34.95 +/- 1.4 degrees and 35.79 +/- 1.36 degrees in control eyes, respectively (P=0.811, P=0.019, P=0.021, P=0.109, P=0.126, P=0.001, and P=0.01, respectively).Conclusions:The depth and width of the anterior chamber in eyes with PEX and in control eyes increased significantly after Nd:YAG laser capsulotomy. The change in the width of the anterior chamber in eyes PEX was statistically significant comparing control eyes.en_US
dc.language.isoengen_US
dc.publisherLippincott Williams & Wilkinsen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectNd:YAG laser Capsulotomyen_US
dc.subjectPosterior Capsule Opacificationen_US
dc.subjectPseudoexfoliationen_US
dc.subjectAnterior-Chamber Depthen_US
dc.subjectAnterior-Chamber Angle Widthen_US
dc.subjectAnterior Segment Optical Coherence Tomographyen_US
dc.titleAnterior segment optical coherence tomography assessment after laser capsulotomy in pseudophakic eyes with pseudoexfoliationen_US
dc.typearticleen_US
dc.relation.ispartofEye & Contact Lens-Science And Clinical Practiceen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalıen_US
dc.authorid0000-0002-2563-2149en_US
dc.authorid0000-0001-9829-7268en_US
dc.authorid0000-0002-8047-5553en_US
dc.identifier.volume42en_US
dc.identifier.issue5en_US
dc.identifier.startpage318en_US
dc.identifier.endpage321en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1097/ICL.0000000000000185en_US
dc.identifier.wosqualityQ3en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster