Effects of varying entry points and trendelenburg positioning degrees in internal jugular vein area measurements of newborns

View/ Open
Access
info:eu-repo/semantics/openAccessDate
2018Author
Karaaslan, PelinDarçın, Kamil
Örmeci̇, Tuǧrul
Karakaya, Muhammet Ahmet
İnce, Ayşe
Aslan, Nesrin Ahu
Taştekin, Ayhan
Metadata
Show full item recordCitation
Karaaslan, P., Darçın, K., Örmeci̇, T., Karakaya, M. A., İnce, A, Aslan, N. ... Taştekin, A. (2018). Effects of varying entry points and trendelenburg positioning degrees in internal jugular vein area measurements of newborns. Nigerian Journal of Clinical Practice, 21(4), 514-518. https://dx.doi.org/10.4103/njcp.njcp_184_17Abstract
Background: Recent guidelines from the National Institute for Clinical Excellence recommend the use of ultrasonography in the central venous catheterization of children. In this study, we aimed to compare area measurements using ultrasonography and efficiency of varying Trendelenburg degrees on the area measurements, for two different entry points used as internal jugular vein (IJV) cannulation points in newborns. Methods: Fifty-eight healthy newborns, weighing between 3000 and 3500 g, were recruited for this prospective study. Right IJV (RIJV) consecutive measurements were performed in three different Trendelenburg positions at 0 degrees, 15 degrees, and 30 degrees, at two different entry points: The superior approach and an inferior approach. The landmark used in the superior approach was the top of the triangle formed by the two heads of the sternocleidomastoid muscle with the clavicle; while in the inferior approach, it was taken as the midpoint of the clavicle, as measured from the upper edge of the clavicle. Results: The cross-sectional area (CSA) of the RIJV was significantly increased when using the inferior approach, compared to that in the superior approach, in all Trendelenburg degrees, including the neutral position. Both 15 degrees and 30 degrees Trendelenburg positioning resulted in a significant increase in CSA, both in superior and inferior approaches, when compared to neutral positioning. Conclusion: The use of 15 degrees Trendelenburg positioning may have significant advantage for increasing the CSA when used with the inferior approach.
WoS Q Kategorisi
Q4xmlui.dri2xhtml.METS-1.0.item-scopusquality
Q3Source
Nigerian Journal of Clinical PracticeVolume
21Issue
4Collections
- Makale Koleksiyonu [3276]
- PubMed İndeksli Yayınlar Koleksiyonu [3583]
- Scopus İndeksli Yayınlar Koleksiyonu [5505]
- WoS İndeksli Yayınlar Koleksiyonu [5678]