Basit öğe kaydını göster

dc.contributor.authorErşahan, Şeyda
dc.contributor.authorAlakuş Sabuncuoğlu, Fidan
dc.contributor.authorAybala Oktay, Elif
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:50:27Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:50:27Z
dc.date.issued2018en_US
dc.identifier.citationErşahan, Ş., Alakuş Sabuncuoğlu, F. ve Aybala Oktay, E. (2018). The efficacy of laser doppler flowmetry, electric pulp test and cold test in diagnosing revascularization of extrusively luxated immature maxillary incisors. Pakistan Journal of Medical Sciences, 34(4), 787-793. https://dx.doi.org/10.12669/pjms.344.15524en_US
dc.identifier.issn1682-024X
dc.identifier.urihttps://dx.doi.org/10.12669/pjms.344.15524
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1989
dc.descriptionWOS: 000442047500003en_US
dc.descriptionPubMed ID: 30190729en_US
dc.description.abstractObjective: To evaluate the effect of extrusion on immature permanent tooth PBF values during a 6-month post-trauma period and to compare the accuracy of cold tests on pulp sensibility of traumatized teeth with that of electric pulp tests (EPT). Methods: The study group comprised of 26 extruded immature maxillary incisors in 25 trauma patients. The respective contralateral homologous teeth (n=25) were included as a positive control group. Teeth in the study group were treated by repositioning and splinting. Pulp vitality readings for traumatized and control teeth were taken with LDF, EPT and cold test on the day of splint-removal (2-3 weeks after trauma-T1) as well as 6 weeks (T2), 3 months (T3) and 6 months (T4) post-trauma. Student t and Mann-Whitney U-tests were used to compare data among groups. Statistical significance was set at P <0.05. Results: LDF gave positive vitality readings (>4.5 PU) in all patients from T1 to T4 (with the exception of 1 patient at T1). Conclusions: LDF was able to accurately identify vitality in traumatized immature teeth even during the first few weeks following trauma, whereas conventional sensibility tests were unable to accurately recognize vitality shortly after trauma.en_US
dc.language.isoengen_US
dc.publisherProfessional Medical Publicationsen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution 3.0 Unported*
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/*
dc.subjectDental Traumaen_US
dc.subjectElectric Pulp Testingen_US
dc.subjectExtrusion Injuryen_US
dc.subjectImmature Teethen_US
dc.subjectLaser Doppler Flowmetryen_US
dc.subjectPulpal Blood Flowen_US
dc.subjectThermal Testingen_US
dc.titleThe efficacy of laser doppler flowmetry, electric pulp test and cold test in diagnosing revascularization of extrusively luxated immature maxillary incisorsen_US
dc.typearticleen_US
dc.relation.ispartofPakistan Journal of Medical Sciencesen_US
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Endodonti Ana Bilim Dalıen_US
dc.authorid0000-0002-0354-5108en_US
dc.identifier.volume34en_US
dc.identifier.issue4en_US
dc.identifier.startpage787en_US
dc.identifier.endpage793en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.12669/pjms.344.15524en_US