Basit öğe kaydını göster

dc.contributor.authorŞerefoğlu Çabuk, Kübra
dc.contributor.authorEsen, Bennur
dc.contributor.authorAtalay, Kürşat
dc.contributor.authorKırgız, Ahmet
dc.contributor.authorAydın, Rukiye
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:50:24Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:50:24Z
dc.date.issued2018en_US
dc.identifier.citationŞerefoğlu Çabuk, K., Esen, B., Atalay, K., Kırgız, A. ve Aydın, R. (2018). Alterations in biomechanical properties of the cornea among patients with polycystic kidney disease. International Ophthalmology, 38(4), 1559-1564. https://dx.doi.org/10.1007/s10792-017-0619-yen_US
dc.identifier.issn0165-5701
dc.identifier.issn1573-2630
dc.identifier.urihttps://dx.doi.org/10.1007/s10792-017-0619-y
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1974
dc.descriptionWOS: 000439166500024en_US
dc.descriptionPubMed ID: 28664236en_US
dc.description.abstractThe aim of this study was to evaluate the corneal biomechanical features in polycystic kidney disease (PKD) patients and compare them with the healthy individuals. Totally 81 patients with a mean age of 48.46 +/- 14.51 years and 60 control cases with a mean age of 44.68 +/- 12.69 years were included in the study. All of the subjects underwent a complete ophthalmological examination, including visual acuity testing, biomicroscopic anterior and posterior segment examinations. Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg) and corneal-compensated intraocular pressure (IOPcc) were evaluated with the ocular response analyzer, and the central corneal thickness was evaluated with Sirius(A (R)) corneal topography. PKD patients had significantly increased CH values, without any alterations in IOP or CCT values, compared with the control cases (p:0.001). Among PKD patients, 23 were having liver cysts accompanying renal cysts. There was not any statistically significant difference between PKD patients with or without liver cysts regarding biomechanical properties of the cornea. However, both patient groups had statistically significantly increased CH values compared with the control cases. Patients with PKD present with higher CH values than age-matched controls. Larger studies are warranted to elucidate the alterations in corneal biomechanical properties and their clinical relevance in PKD patients.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBiomechanicsen_US
dc.subjectCorneaen_US
dc.subjectPolycystic Kidney Diseaseen_US
dc.titleAlterations in biomechanical properties of the cornea among patients with polycystic kidney diseaseen_US
dc.typearticleen_US
dc.relation.ispartofInternational Ophthalmologyen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalıen_US
dc.authorid0000-0003-0668-3749en_US
dc.identifier.volume38en_US
dc.identifier.issue4en_US
dc.identifier.startpage1559en_US
dc.identifier.endpage1564en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1007/s10792-017-0619-yen_US
dc.identifier.wosqualityQ3en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster