Basit öğe kaydını göster

dc.contributor.authorDikkaya, Funda
dc.contributor.authorYıldırım, Rengin
dc.contributor.authorKaraman Erdur, Sevil
dc.contributor.authorBenbir, Gülçin
dc.contributor.authorAydın, Rukiye
dc.contributor.authorKaradeniz, Derya
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:50:01Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:50:01Z
dc.date.issued2018en_US
dc.identifier.citationDikkaya, F., Yıldırım, R., Karaman Erdur, S., Benbir, G., Aydın, R. ve Karadeniz, D. (2018). Corneal biomechanical properties in obstructive sleep apnea syndrome. Eye & Contact Lens-Science and Clinical Practice, 44(Supplement: 2), S361-S364. https://dx.doi.org/10.1097/ICL.0000000000000489en_US
dc.identifier.issn1542-2321
dc.identifier.issn1542-233X
dc.identifier.urihttps://dx.doi.org/10.1097/ICL.0000000000000489
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1852
dc.descriptionWOS: 000457840400061en_US
dc.descriptionPubMed ID: 29420326en_US
dc.description.abstractObjectives: To investigate the corneal biomechanical properties and anterior segment parameters in patients with obstructive sleep apnea syndrome (OSAS). Methods: Fifty-four eyes of 54 patients with OSAS and 20 eyes of 20 healthy subjects were included. Patients with mild and moderate OSAS (Respiratory Disturbance Index [RDI] <30) enrolled in group 1, those with severe OSAS (RDI>= 30) in group 2 and controls in group 3. Corneal biomechanical properties including corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated intraocular pressure (IOPcc) were measured with ocular response analyzer. Maximum (Kmax), minimum (Kmin), and mean simulated (SimKm) keratometry values, corneal astigmatism (CA), and central corneal thickness (CCT) were evaluated with Pentacam Scheimpflug imaging. Results: The mean CH and CRF were significantly lower in group 2. The mean CH was 10.9 +/- 1.4 mm Hg in group 1,10.1 +/- 1.1 mm Hg in group 2, and 12.1 +/- 1.2 mm Hg in group 3 (P<0.001). The mean CRF was 11.1 +/- 1.8 mm Hg in group 1, 9.9 +/- 1.1 mm Hg in group 2, and 12.2 +/- 1.2 mm Hg in group 3 (P<0.001). The CH and CRF values were similar between the groups 1 and 3 (P = 0.867 and P = 0.743). Corneal-compensated intraocular pressure, IOPg, Kmax, Kmin, SimKm, CA, and CCT values were not statistically different among the three groups. Conclusions: Patients with severe OSAS had lower CH and CRF values. The lower CH and CRF values in the severe group were possibly related to changes of the structural properties in the cornea.en_US
dc.language.isoengen_US
dc.publisherLippincott Williams & Wilkinsen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectCorneal Biomechanical Propertiesen_US
dc.subjectCorneal Hysteresisen_US
dc.subjectCorneal Resistance Factoren_US
dc.subjectObstructive Sleep Apnea Syndromeen_US
dc.subjectAnterior Segment Parametersen_US
dc.titleCorneal biomechanical properties in obstructive sleep apnea syndromeen_US
dc.typearticleen_US
dc.relation.ispartofEye & Contact Lens-Science and Clinical Practiceen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalıen_US
dc.authorid0000-0003-2312-2521en_US
dc.authorid0000-0001-9829-7268en_US
dc.authorid0000-0003-0668-3749en_US
dc.identifier.volume44en_US
dc.identifier.issueSupplement: 2en_US
dc.identifier.startpageS361en_US
dc.identifier.endpageS364en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1097/ICL.0000000000000489en_US
dc.identifier.wosqualityQ3en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster