Basit öğe kaydını göster

dc.contributor.authorEyecioğlu, Önder
dc.contributor.authorEl-Khayatt, Ahmed Mahmoud
dc.contributor.authorKarabul, Yaşar
dc.contributor.authorÇağlar, Mustafa
dc.contributor.authorToker, Ozan
dc.contributor.authorİçelli, Orhan
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:49:35Z
dc.date.available10.07.201910:49:13
dc.date.available2019-07-10T19:49:35Z
dc.date.issued2019en_US
dc.identifier.citationEyecioğlu, Ö., El-Khayatt, A. M., Karabul, Y., Çağlar, M., Toker, O. ve İçelli, O. (2019). BXCOM: A software for computation of radiation sensing. Radiation Effects and Defects In Solids, 174(5-6), 506-518. https://dx.doi.org/10.1080/10420150.2019.1606811en_US
dc.identifier.issn1042-0150
dc.identifier.issn1029-4953
dc.identifier.urihttps://dx.doi.org/10.1080/10420150.2019.1606811
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1669
dc.descriptionWOS: 000469740700001en_US
dc.description.abstractThe main objective of this work is to develop user-friendly software, called BXCOM, for computation of the exposure build-up factor (EBF) and the energy absorption build-up factor (EABF), using geometric progression (G-P) fitting method for element, compound or mixture in the energy region 0.015-15 MeV, and for penetration depths up to 40 mean free path (mfp). Furthermore, BXCOM can generate the equivalent atomic number and five fitting parameters used in the G-P method for mixtures and compounds over an interval of photon energies extended from 0.015 to 15 MeV. In addition, the program is designed to calculate the effective atomic number and effective electron number via the direct method. BXCOM program has been verified by comparing its results with approved data by American National Standards Institute. BXCOM runs under MS Windows (R) operating system. It has an improved user interface that provides examination of material's radiation interaction parameters. Finally, BXCOM allows rapid and reliable calculation of many gamma-ray interaction parameters such as , , , G-P fitting parameters and build-up factors that are essential in a wide range of applications such as radiation shielding, radiotherapy, technology and so on.en_US
dc.description.sponsorshipTurkiye Bilimsel ve Teknolojik Arastirma Kurumu [2015-115F311]en_US
dc.description.sponsorshipThis work was supported by Turkiye Bilimsel ve Teknolojik Arastirma Kurumu [Grant Number 2015-115F311].en_US
dc.language.isoengen_US
dc.publisherTaylor & Francis Ltden_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectEnergy Absorption Build-Up factoren_US
dc.subjectExposure Build-Up Factoren_US
dc.subjectBXCOMen_US
dc.subjectSoftwareen_US
dc.titleBXCOM: A software for computation of radiation sensingen_US
dc.typearticleen_US
dc.relation.ispartofRadiation Effects and Defects In Solidsen_US
dc.departmentİstanbul Medipol Üniversitesi, Sağlık Hizmetleri Meslek Yüksekokulu, Tıbbi Görüntüleme Teknikleri Ana Bilim Dalıen_US
dc.authorid0000-0002-0106-7683en_US
dc.identifier.volume174en_US
dc.identifier.issue5-6en_US
dc.identifier.startpage506en_US
dc.identifier.endpage518en_US
dc.relation.ecinfo:eu-repo/grantAgreement/TUBITAK/SOBAG/2015- 115F311en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1080/10420150.2019.1606811en_US
dc.identifier.wosqualityQ4en_US
dc.identifier.scopusqualityQ3en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster