dc.identifier.citationİzgi, E. ve Pekiner, F. N. (2019). Comparative evaluation of conventional and OnyxCeph™ dental software measurements on cephalometric radiography. Turkish Journal of Orthodontics, 32(2), 87-95. https://dx.doi.org/10.5152/TurkJOrthod.2019.18038en_US
dc.identifier.issn2528-9659
dc.identifier.issn2148-9505
dc.identifier.urihttps://dx.doi.org/10.5152/TurkJOrthod.2019.18038
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1623
dc.descriptionWOS: 000472965000005en_US
dc.description.abstractObjective: Cephalometry can be measured with traditionally conventional analysing methods (hand tracing), as well as using computers. Many dental softwares have been developed for this purpose. The reliability of these programs are often compared with the conventional method. The aim of the present study was to compare the conventional method of manual cephalometric analysis with a computerized one, OnyxCeph (TM) (Image Instruments, Chemnitz, Germany) dental software. Methods: Lateral cephalometric radiographs of 150 patients (75 males and 75 females) age range 12-34 were traced by two methods. Conventional method and computerized (OnyxCeph) cephalometric analysis method. 2 maxillar, 3 mandibular, 2 maxillo-mandibular, 3 vertical, 7 dental and 1 soft tissue parameters; 10 angular, 8 linear totally 18 cephalometric parameters were measured. Intra-class correlation coefficients were performed for both methods to assess the reliability of the measurements. Results: The results 9 of 18 parameters were found statistically significant. They were Cd-A distance, Cd-Gn distance, Go-Me distance, GoGnSN angle, ANS-Me distance, upper incisor-NA distance, lower incisor-NB distance, lower incisor-NB angle, overbite distance. Conclusion: Despite some discrepancies in measured values between hand-tracing cephalometric analysis method and the OnyxCeph cephalometric analysis method, statistical differences were minimal and only Cd-A, Cd-Gn, Go-Me, ANS-Me, GoGnSN degrees were clinically important for cephalometric analysis OnyxCeph was evaluated as an efficient method to replace conventional method.en_US
dc.language.isoengen_US
dc.publisherAvesen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCephalometricsen_US
dc.subjectManual Tracingen_US
dc.subjectOnyxcephen_US
dc.subjectComputerized Cephalometric Programen_US
dc.subjectReliabilityen_US
dc.titleComparative evaluation of conventional and OnyxCeph™ dental software measurements on cephalometric radiographyen_US
dc.typearticleen_US
dc.relation.ispartofTurkish Journal of Orthodonticsen_US
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalıen_US
dc.authorid0000-0001-7426-5587en_US
dc.identifier.volume32en_US
dc.identifier.issue2en_US
dc.identifier.startpage87en_US
dc.identifier.endpage95en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.5152/TurkJOrthod.2019.18038en_US