Basit öğe kaydını göster

dc.contributor.authorKızılırmak, Filiz
dc.contributor.authorGünhan Demir, Gültekin
dc.contributor.authorGökdeniz, Tayyar
dc.contributor.authorGüneş, Hacı Murat
dc.contributor.authorÇakal, Beytullah
dc.contributor.authorGüler, Ekrem
dc.contributor.authorKaraca, İbrahim Oğuz
dc.contributor.authorOmaygenç, Mehmet Onur
dc.contributor.authorYılmaz, Fatih
dc.contributor.authorOlgun, Fatih Erkam
dc.contributor.authorKılıçaslan, Fethi
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:37:37Z
dc.date.available10.07.201910:49:14
dc.date.available2019-07-10T19:37:37Z
dc.date.issued2016en_US
dc.identifier.citationKızılırmak, F., Günhan Demir, G., Gökdeniz, T., Güneş, H. M., Çakal, B., Güler, E. ... Kılıçaslan, F. (2016). Changes in electrocardiographic p wave parameters after cryoballoon ablation and their association with atrial fibrillation recurrence. Annals of Noninvasive Electrocardiology, 21(6), 580-587. https://dx.doi.org/10.1111/anec.12364en_US
dc.identifier.issn1082-720X
dc.identifier.issn1542-474Xen_US
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1441
dc.identifier.urihttps://dx.doi.org/10.1111/anec.12364
dc.description.abstractBackground: Changes in P wave parameters after circumferential pulmonary vein isolation (CPVI) have been previously identified. In this study, we aimed to determine the changes in P wave parameters surface electrocardiogram (ECG) after cryoballoon ablation (CBA) for atrial fibrillation (AF) and evaluate their relationship with AF recurrence. Methods: Sixty-one patients (mean age 53 ± 11 years, 50.8% male) with paroxysmal AF who underwent CBA were enrolled. A surface ECG was obtained from all patients immediately before the procedure, and repeated 12 hours after the procedure. P wave amplitude (Pamp), P wave duration (Pwd), and P wave dispersion (Pdis) values in preprocedural and postprocedural ECGs were measured and compared. Recurrence rates of AF in 3, 6, and 9 months following ablation were recorded for all patients. Changes in P wave parameters were compared between patients with and without AF recurrence. Results: Compared to preprocedural measurements, Pamp (from 0.58 ± 0.18 mV at baseline to 0.48 ± 0.17 mV, P < 0.001), Pwd (from 109.72 ± 18.43 ms at baseline to 91.36 ± 22.53 ms, P < 0.001), and Pdis (from 55.44 ± 20.45 ms at baseline to 45.30 ± 15.31 ms, P < 0.001) were significantly decreased after CBA. The difference in Pamp between pre- and postprocedural values (?Pamp) was significantly higher in patients without AF recurrence compared to those with recurrence (0.10 ± 0.06 mV vs 0.04 ± 0.01 mV, P = 0.002). There was no difference in Pwd difference (?Pwd) and Pdis difference (?Pdis) between patients with and without AF recurrence (P > 0.05). Conclusion: Pamp, Pwd, and Pdis parameters exhibited significant decrease after CBA compared to preprocedural measurements. Decreased Pamp was shown to be a predictor for good clinical outcomes following CBA.en_US
dc.language.isoengen_US
dc.publisherWiley-Blackwellen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAtrial Arrhythmiasen_US
dc.subjectAtrial Fibrillationen_US
dc.subjectElectrocardiographyen_US
dc.subjectElectrophysiologyen_US
dc.subjectNoninvasive Techniquesen_US
dc.titleChanges in electrocardiographic p wave parameters after cryoballoon ablation and their association with atrial fibrillation recurrenceen_US
dc.typearticleen_US
dc.relation.ispartofAnnals of Noninvasive Electrocardiologyen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Kardiyoloji Ana Bilim Dalıen_US
dc.authorid0000-0003-1919-3183en_US
dc.authorid0000-0001-9975-5507en_US
dc.authorid0000-0003-0230-6575en_US
dc.authorid0000-0002-4607-5724en_US
dc.authorid0000-0002-4281-0867en_US
dc.authorid0000-0003-2995-8792en_US
dc.identifier.volume21en_US
dc.identifier.issue6en_US
dc.identifier.startpage580en_US
dc.identifier.endpage587en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1111/anec.12364en_US
dc.identifier.wosqualityQ4en_US
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster