Basit öğe kaydını göster

dc.contributor.authorKara, Adnan
dc.contributor.authorÇelik, Haluk
dc.contributor.authorŞeker, Ali
dc.contributor.authorUysal, Mehmet Ali
dc.contributor.authorUzun, Metin
dc.contributor.authorMalkoç, Melih
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:37:09Z
dc.date.available10.07.201910:49:14
dc.date.available2019-07-10T19:37:09Z
dc.date.issued2014en_US
dc.identifier.citationKara, A., Çelik, H., Şeker, A., Uysal, M. A., Uzun, M. ve Malkoç, M. (2014). Granuloma formation secondary to Achilles tendon repair with nonabsorbable suture. International Journal of Surgery Case Reports, 5(10), 720-722.https://dx.doi.org/10.1016/j.ijscr.2014.07.026en_US
dc.identifier.issn2210-2612
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1340
dc.identifier.urihttps://dx.doi.org/10.1016/j.ijscr.2014.07.026
dc.description.abstractCONCLUSION: Although Ethibond suture is a strong and safe material for Achilles tendon repairs it may cause soft tissue problems such as granuloma.INTRODUCTION: Several complications can be observed after Achilles tendon repairs. In this study we aimed to report granuloma formation secondary to Achilles tendon repair with Ethibond (Ethicon INC, Somerville, New Jersey) suture.PRESENTATION OF CASE: A 31 year-old man operated for Achilles tendon rupture. The Ethibond suture was used for primary repair. The patient attended to polyclinic with the complaints of swelling and discharge around the operation site four months after operation. A mass around distal portion of the Achilles tendon was detected. The granulomatous tissue was excised. Inside the mass Ethibond suture was detected. On histopathologic examination, typical findings of the foreign body reaction were observed. No microorganism was cultivated in the tissue culture. The patient has no complaint on the twelfth month control after surgery.DISCUSSION: The results of primary repair of Achilles tendon are good but several complications were reported. In tendon repairs generally nonabsorbable sutures are used. The Ethibond is nonabsorbable, braided suture. In the literature, granuloma formations secondary to the suture materials such as polygylactine and braided polyethylen-polyester after Achilles tendon repair were reported but granuloma secondary to the Ethibond is very rare.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Unported*
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/3.0/*
dc.subjectAchilles Tendon Repairen_US
dc.subjectEthibonden_US
dc.subjectGranuloma Formationen_US
dc.titleGranuloma formation secondary to achilles tendon repair with nonabsorbable sutureen_US
dc.typearticleen_US
dc.relation.ispartofInternational Journal of Surgery Case Reportsen_US
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Ortopedi ve Travmatoloji Ana Bilim Dalıen_US
dc.authorid0000-0003-4798-1400en_US
dc.authorid0000-0003-1259-6668en_US
dc.authorid0000-0002-4843-5121en_US
dc.identifier.volume5en_US
dc.identifier.issue10en_US
dc.identifier.startpage720en_US
dc.identifier.endpage722en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.ijscr.2014.07.026en_US
dc.identifier.scopusqualityQ3en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster

info:eu-repo/semantics/openAccess
Aksi belirtilmediği sürece bu öğenin lisansı: info:eu-repo/semantics/openAccess