Procedural outcomes of double vs. single fluoroscopy for fixing intertrochanteric femur fractures
(Springer Verlag, 2016)
Objective: This study compares reducing radiation and operation time between single and double C-arm fluoroscopy in the treatment of intertrochanteric femur fractures with intramedullary nails. Patients and methods: Forty ...
Treatment of open fractures with a computer-assisted external fixator system without the use of fluoroscopy
(BMC, 2016)
Background: Developed for the treatment of deformity correction, computer-assisted circular external fixators in recent years have also been used for fracture fixation. In this study, we aimed to present the efficacy of ...