Çakan, UmutÇakan, MuratDelilbaşı, Çağrı10.07.20192019-07-1010.07.20192019-07-102016Çakan, U., Çakan, M. ve Delilbaşı, Ç. (2016). Evaluation of heat transfer to the implant-bone interface during removal of metal copings cemented onto titanium abutments. International Journal Of Prosthodontics, 29(3), 290-292. https://dx.doi.org/10.11607/ijp.45610893-21741942-4426https://dx.doi.org/10.11607/ijp.4561https://hdl.handle.net/20.500.12511/2829WOS: 000376213500018PubMed ID: 27148993Purpose: The aim of this investigation was to measure the temperature increase due to heat transferred to the implant-bone interface when the abutment screw channel is accessed or a metal-ceramic crown is sectioned buccally with diamond or tungsten carbide bur using an air rotor, with or without irrigation. Materials and Methods: Cobalt-chromium copings were cemented onto straight titanium abutments. The temperature changes during removal of the copings were recorded over a period of 1 minute. Results: The sectioning of coping with diamond bur and without water irrigation generated the highest temperature change at the cervical part of the implant. Conclusion: Both crown removal methods resulted in an increase in temperature at the implant-bone interface. However, this temperature change did not exceed 47 degrees C, the potentially damaging threshold for bone reported in the literature.eninfo:eu-repo/semantics/openAccessEvaluation of HeatImplant-BoneRemoval of Metal CopingsCemented Onto Titanium AbutmentsEvaluation of heat transfer to the implant-bone interface during removal of metal copings cemented onto titanium abutmentsArticle29329029210.11607/ijp.4561Q4Q1